PLUG IN RECEIVER

CITY1-ECD is suitable for plugging in a Personal Pass MR1
receiver having a high-sensitivity super-heterodyne architecture.
WARNING: it is necessary to turn off the control unit
power before doing the operations mentioned here below.
Pay attention to the way you connect the removable
modules.
MR1 module receiver is provided with 4 channels and each of
them is suitable for a command of CITY1-ECD control unit:
• CHANNEL 1
START
• CHANNEL 2
PEDESTRIAN START
• CHANNEL 3
STOP
• CHANNEL 4
OPTIONAL MODULS OUTPUT
WARNING: Before programming 4 channels and
function logics read carefully the instructions of MR1.

OPTIONAL MODULES

The ADI (Additional Devices Interface) interface of the control
unit CITY1-ECD allows the connection to V2 optional modules.
Its dedicated connector has been placed over the word OPTIONS
Refer to V2 catalogue or to the technical sheets to see which
optional modules with ADI interface are available for this control
unit.
WARNING: Please read the instructions of each single
module to install the optional modules.
For some devices, it is possible to configure the mode for
interfacing with the control unit; in addition, it is necessary to
enable the interface so that the control unit can process the
signals arriving from the ADI device.
Please refer to the i.ADi programming menu to enable the ADI
interface and access the device configuration menu.
The ADI device can signal photocell, edge or stop alarms:
• Photocell alarms - the gate stops moving, when the alarm
stops opening restarts.
• Edge alarm - inverts motion of the gate for 3 seconds.
• Stop alarm - the gate stops and cannot restart until the alarm
stops.

CONTROL PANEL

When power is on, the control unit checks that display correctly
operates by switching on all segments for 1.5 sec. 8.8.8.8.
Firmware version, e.g. Pr 2.4, will be viewed in the following
1.5 sec. Panel will be viewed upon completion of this test.
The control panel represents the physical status of the
terminal board contacts and of the program mode keys: if the
upper vertical segment is on, the contact is closed; if the lower
vertical segment is on, the contact is open (the above picture
shows an instance where the inputs START, START P, FOTO 1,
FOTO 2,COSTA 1, COSTA 2 and STOP have all been correctly
connected).
Points being among display digits show the status of
programming push-buttons: as soon as a push-button is pressed,
its relevant point turns on.
The arrows on the display left side show the status of the ends of
stroke. As for a one door-gate, arrows turn on when its end of
stroke shows that the gate is completely closed or
completely open.
As for a two-door gate, arrows turn on when both the ends of
stroke show that both the doors are completely closed or
completely open; the arrow will blink in case only one door
reaches its end of stroke.
WARNING: these functions have not been activated in
case of ends of stroke being connected in series to the
motor.
The arrows on the display right side show the gate status:
• The highest arrow turns on when the gate is into its opening
phase. If it blinks, it means that the opening has been
caused by a safety device (border or obstacle detector).
• The central arrow shows that the gate is on pause. If it
blinks, it means that the time countdown for the automatic
closing has been activated.
• The lowest arrow blinks when the gate is into its closing
phase. If it blinks, it means that the closing has been
caused by a safety device (border or obstacle detector).
32