Stop Input - V2 CITY1-ECD Manual Del Usuario

Cuadro de maniobras digital para cancelas batientes y puertas correderas
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Pause after transit
In order to let the gate open for the shortest possible time, it is possible
to stop the gate once the passage before the photocells is detected. If
the automatic working is enabled, the time of the pause is Ch.tr.
If the photocells are type 1 and type 2, the gate enters the phase of
pause only after the detections before both the photocells.
Blinker during pause time
Blinker usually operates during the gate motion only; however, if this
function is enabled, blinker will be on during the pause time too.
Start input function
This menu allows selecting input operation modes (see paragraph
"Activation inputs"):
StAn
Start and Pedestrian Start input standard operation,
according to menu setups.
no
Start inputs from terminal board are disabled. Radio inputs
operate in StAn mode.
AP.CH
Start impulse always controls the opening phase, Pedestrian
Start always controls the closing phase.
PrES
Manned operation; the gate will open as long as the Start
input stays closed and it will close as long as Pedestrian
Start stays closed.
oroL
Timer-operation; the gate stays open while the Start input or
Pedestrian Start input is closed; as soon as the contact
opens, the pause count down will start.

Stop Input

This menu permits to select the functions associated to the
command of STOP.
no
The input STOP is not available.
ProS
The input STOP stops the gate: pressing the command START
the gate continues the motion.
invE
The command STOP stops the gate: at the next START the
gate starts moving in the opposite direction.
The setting of parameter STOP determines also in which direction the
gate will move at the next START, if it has stopped because of an
intervention of the safety edges or the obstacle sensor. If you set no, the
START command restarts the motion in the same direction.
NOTE: during the pause, the STOP command will stop the pause time
count, the next START command will always close the gate.
41

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

City1-ecd-120v

Tabla de contenido