V2 CITY1-ECD Manual Del Usuario página 41

Cuadro de maniobras digital para cancelas batientes y puertas correderas
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Slowing down time
In case this function is enabled, during the last seconds of motion of
each door, the control unit will give motors a reduced power command,
to avoid a strong impact with the stop end. t.AP1 is the max. allowed
time.
WARNING:
• In case the self-learning function of working times is NOT used, we
recommend disabling the slowing down function in order to measure
both opening and closing times, and to enable it again once the setup
has been carried out. The control unit will automatically consider the
working time delay caused by the slowing down.
• If partial opening time t.APP is shorter than t.AP1, there will be no
slowing down during the pedestrian cycle opening.
PLEASE NOTE (USE OF HYDRAULIC MOTORS):
This function might NOT work correctly if hydraulic motors are
used. In this case, the functions should be disabled in the menu.
Fast closing time after slowing down
If a slowing time other than 0 is set up, it could be likely that the gate
speed is not enough for the lock to fasten during the closing phase.
In case this function is enabled, once the slowing down phase is
finished, the control unit will give a normal speed command (that is to
say, with no slowing down) for the set up time, and then it will open
the gate for a second fraction, to avoid leaving the motor under stress.
PLEASE NOTE: Set to 0 if the gate is not fitted with
electro-locks or if slowing is disabled.
Enabling the motor test
When the motors are not connected directly to the main terminal board,
but controlled by relay or remote switches, the control devices are not
sufficiently charged and the motor function test might fail.
This menu allows motor control device verification to be enabled or
disabled prior to each cycle.
Si
test enabled
no
test disabled
PLEASE NOTE: This test is important for safe use of the
gate. V2 recommends disabling the test ONLY when the control
unit is not connected directly to the motors.
Start command during the opening phase
This menu allows fixing the control unit conduct in case it receives a
Start command during the opening phase.
PAUS
The gate stops and goes to pause.
ChiU
The gate immediately starts closing.
no
The gate go on with the opening phase (command is ignored).
Select option PAUS, to set up the "step-by-step" operation logic.
Select option 'no', to set up the 'always open' operation logic.
39

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

City1-ecd-120v

Tabla de contenido