Press
2
3
4
5
6
10 Confi guration parameters
1
Analogue input AN1:
Type of thermocouple
0
Type K (-50/1300 °C)
1
Type J (-50/1200 °C)
2
Type S (-50/1800 °C)
3
Type R (-50/1800 °C)
2
Limits of the scale (0/3200 °C or °F):
This parameter defi nes the maximum temperature of the kiln.
Display
Flashing digit changes.
Display
fl ashing.
Press this key to scroll through
all the parameters.
Increase or decrease the value.
End of confi guration. The
controller is set as STOP-mode.
Do
Enter password
STEP to skip to next number
and then to display the 1
parameter.
When the display reaches the
required parameter, wait for a
few seconds for it to change to
the value.
Enter the new value (see par.
8.1 to change numeric value).
To change a new parameter
return to point 4.
. Press
st
17
GB