These parameters set the values for P.I.D. control mode. In case of ON/
OFF modulation (proportional band set to 0), parameter P-10 acts as
hysteresis.
  
11
Measure units:
Units of temperature measurement
0
°C
1
°F
 
12
Delayed start:
Programming of delayed start (entering step 0) and Autotuning function
0
Step 0 enabled
1
Step 0 disabled
2
Step 0 enabled
3
Step 0 disabled
 
13
Treshold for alarm (0/3200 °C or °F):
This parameter defi nes the treshold for alarm intervention.
 
14
Change of setpoint value during a fi ring curve:
This parameter allows the setpoint values to be modifi ed during a fi ring.
0
Setpoint change disabled
1
Setpoint change enabled
 
15
Power consumption of the kiln (0.0/999.9 – Kwatt/h):
This parameter defi nes the power of the plant. If the value has been
entered, press the key STEP after cycle end to visualize the power
consumption Kwatt/h for the last cycle. The value gets lost when the
controller is switched off .
 
16
Function WAITING (0/9999 minutes):
This parameter allows to set a fi xed waiting time in case that setpoint
value is not reached. If parameter is set to zero, the function is desabled.
 
17
Function RECOVERY:
Recovery of interrupted cycle and fi ring prosecution after a black-out.
0
Recovery excluded
1
Recovery enabled
Auto-tune disabled
Auto-tune enabled
Auto-tune enabled
Auto-tune disabled