TROUBLESHOOTING
PROBLEM
1. No power supply.
2. Damaged wiring or loose
LED control
connection.
panel lights
3. Wiring not attached to control
do not light
panel switch.
up.
4. Defective switch.
5. Defective LEDs.
Cooking light
1. No power supply.
will not turn
2. Defective Halogen bulb.
on.
3. Internal wiring issue.
POSSIBLE CAUSE
CORRECTIVE ACTION
1. Install 9V batteries in the LED battery
box.
2. Check all wiring connections between
the battery box and the LED. Also
check the connections between the
LEDs on the control panel.
3. Check the connection between the
LED and the LED switch.
4. Replace the switch.
5. Replace the LED.
1. Check power supply and make sure it
is properly plugged in.
2. Replace the bulb.
3. Check the wiring connections under
the fire box. All wire connections must
be tight. If any wires are damaged
they should be replaced.
34