8. INSTALL THE ADAPTER (INTERIOR BLOWER)
Using two standard 1/2" screws, secure the adapter to the top (or back) of the hood. Seal the adapter to the hood using metal foil duct tape.
NOTE: For vertical exhaust, ensure that the damper pivot is located towards the front of the hood.
HD0005
9. INSTALL THE HOOD (INTERIOR & EXTERIOR BLOWER)
INTERIOR BLOWER: Run power cable to installation location. Place the hood to its location. Mark the position of the screws (smaller
part of the key holes) with a pen. Remove the hood and install the (8) 1/2" double thread screws leaving a 1/8" gap
(4 screws for 30" hood). Remove wiring cover, place the wire clamp, insert the cable in the hood and tighten the wire
clamp to secure the cable. Place the hood under the cabinet and slide it in position. Make sure the adapter/damper
assembly enters the ducting. Secure the hood by tightening the screws completely.
HD0043
IN-LINE OR EXTERIOR BLOWER: Run power cable to installation location. Place the hood to its location. Mark the position of the screws
(smaller part of the key holes) with a pen. Remove the hood and install the (8) 1/2" double thread
screws leaving a 1/8" gap (4 screws for 30" hood). Remove wiring cover on top of the hood and
connect wiring (see instructions included with exterior blower). Place the hood under the cabinet and
slide it in position. Secure the hood by tightening the screws completely.
HD0006
8