1.12.5. Diagram for heat-resistant panel
1.13. Deflexed Panel assembly
1.14. Rectangular piece that control the load. Once placed all refractory pieces, place the
two pieces of control the load, so that they remain among the pieces A and A both sides of the
base burning.
1.15. Cleaning and maintenance. It is highly recommended an accessible zone for the
leaning of the apparatus, smoke chamber and smokestack.
2 – USER'S GUIDE
ALL LOCAL REGULATIONS, INCLUDING THE ONES ACCORDING TO THE NATIONAL OR
EUROPEAN NORMS MUST BE ACCOMPLISHED WHEN PROCEEDING TO INSTALL THE
FIREPLACE.
Warning: Do not operate or handle any part when the fireplace is working unless using
the exothermic glove.
2.1. Using for the first time. For early on, and for a reasonable time, the fuel load should not
exceed 50% C.M.A. (Maximum fuel load authorised by the manufacturer).
2.2. Fire control. To obtain the correct performance, do as it follows:
Primary register
2.2.1. Mono-command register
light the fire and regulate fire intensity, when sliding it from left to right, it activates the primary
register. The other way around, it activates the secondary one. The more closed, the dirtier.
ATTENTION:
The positions indicated are according to technical characteristics table, in any case
these positions must be adapt according to the flue depression and fuel quality.
2.3. Security distances. Furniture, objects and the rest of flammable or fragile things (textile,
electronic devices, wood, wall paper, glass, chalk etc) must be, at least, at a distance of 1000
mm away from the fireplace and outer walls of the chimney. The hot air outlets distance must
also be taken into account in a distance of 250 mm.
2.4. Fire types. This apparatus is an on and off fire. The smoke chamber must be closed except
when being loaded, to avoid any smoke out fuel debris. It is convenient when loading the
fireplace, to avoid any leak or smoke escape.
2.5. Authorised fuel. The apparatus must not be used as an incinerating device. Only logs of
natural wood are recommended, humidity within 12 and 20 % . It is highly recommended the
use of at least 2 year-old logs. The use of other types of fuel is forbidden, as well as any liquid
used to light barbecue fires. Their maximum length might not be longer than 550 mm.
2.6. Loading and reload fuel. It must take into account the maximum authorised load of fuel,
ensuring that when the recharge it does not exceed 175 mm in height and taking care not to
exceed either in quantity or size to the data specified above.
To make the procedure ignition follow these steps: placing the burden on the central area of the
database from home, open the register primary and secondary maximum and then fire pledge
(27-28).
44%
open
It is situated off the outdoor frames It is basically used to
(29).
.
3 Units of panels 400x200x30 (A)
2 Units of panels 80x400x30 (B)
4 Units of panels 500x200x30 (C)
1.Panels of 80x400x30
2.Panels of 400x200x30
3.Panels of 500x200x30
It must be placed at the top part of the lids in each side.
Secondary register 7%
Components:
Colocación:
open
Página 16 de 19