single independent unit. Place a spirit
level on the structure (detail D).
Adjust the levelling feet (detail E) ac-
cording to the indications provided by
the level.
Perfect levelling is achieved by
adjusting level and feet on the wi-
dth and depth of the appliance.
"SERIES" ASSEMBLY / see SECT.
IMAGES - REF. c).
Remove the knobs and unscrew the
screws for the fixing of the panel on
both appliances (detail F).
Flammable walls / The minimum
distance of the appliance from
the side walls must be 10 cm and
from the rear wall must be 20 cm. If it is
lower, insulate the walls close to the ap-
pliance with fireproof and / or insulating
treatments.
Place the equipments in order to make
Before proceeding with the opera-
tions, see "General safety infor-
mation".
These operations must be per-
formed by qualified and author-
ised operators, in accordance
with the laws in force and using the
appropriate materials described.
Generally, the appliance is de-
livered without electric mains
supply cable, without pipes for
connection to the water, drainage
and gas networks.
ELECTRICAL CONNECTION
Electrical connection should be per-
THE PRESENT MANUAL IS PROPERTY OF THE MANUFACTURER. ANY REPRODUCTION, EVEN PARTIAL, IS PROHIBITED.
POSITIONING AND HANDLING
their sides perfectly adhere (detail G).
Carry out the appliance levelling as pre-
viously described (detail E).
To place the equipment adherent each
other perfectly (part G). Level the
equipment as described above (detail
E). Remove the protective caps (part
H2). Insert the screws in their housings
and lock the two structures with the
locking nuts (part H1-H3). Replace the
protective caps between the devices
(part H2). Repeat, if necessary, the se-
quence of leveling and fixing operations
for the remaining equipment.
INTRODUCTION
(OPTIONAL)) see SECT. IMAGES
- REF. c) / In order to introduce the
terminal, position it and fix it with the
equipped screws provided (detail L1).
Once the described operations have
been carried out, position again the pa-
nels and knobs of the different applian-
ces in the respective housings.
POWER SUPPLY CONNECTIONS
formed in compliance with the local
regulations in force, only by authorised
and competent personnel. In the first
instance, examine the data shown on
the technical data table of this manual,
on the serial plate and on the electrical
diagram.
Connect the equipment to an
overvoltage category III omnipolar
device.
EARTHING / It is essential to earth
the unit.To this purpose, it is ne-
cessary to connect to an efficient
earthing system the terminals marked
with the symbols placed on the line-recei-
ving terminal box. The earthing system
should comply with the local law in force.
- 10 -
OF
TERMINAL
4.