In standard 4T, the duration of the Pre-gas or HotStart and the Post gas or Crater filler is managed by the trigger.
2T Pulse process:
T hotstart
Dstart
Soft-start
When the trigger is pulled, the Pre-gas starts. When the wire touches the part, a pulse initiates the arc. Then the machine starts with the HotStart,
Upslope and eventually the welding cycle starts. When the trigger is released, the Downslope starts to reach ICrater filler. Then the stop peak cuts the
wire followed by the Post gas. As in «Standard», the user has the possibility to quickly restart the welding during the Post gas without going through
the HotStart phase.
4T Pulse process :
T hotstart
Dstart
4T
OFF
Soft-start
En 4T pulse, la gâchette gère le Pré-gaz s'il n'y a pas de HotStart. Sinon elle permet de gérer la durée du HotStart, s'il est validé.v During the shu-
tdown, it allows to manage the Crater filler, if it is validated or the Post gas if there is no Crater filler.
PULSFEED 4W
T upslope
T upslope
I
T downslope
I
T downslope
I blackout
Gas post-Flow
T burn-back
T crater Filler
I crater Filler
I Blackout
Gas post-Flow
T burn-back
4T
T crater Filler
I crater Filler
EN