5.3. Changing the battery pack 
To change the battery pack remove the 4 screws (7) that attach it to the main body of the ventilation unit. 
6. STORAGE, CONSERVATION AND TRANSPORT 
The materials used have excellent anti‐ageing characteristics, and therefore one does not need to take any special 
precaution  in  the  conservation  of  the  device,  however  it  is  advisable  to  keep  the  respirators  in  their  original 
packaging  in  well  ventilated  warehouses,  away  from  chemical  vapours  and  from  any  heat  source,  within  a 
temperature range of ‐20 °C and + 50 °C and in less than 80% humidity (refer to the pictograms shown on the sales 
package, on the TURBINE 170 and at the end of these instructions).  
The  devices,  stored  in  their  original  packaging,  do  not  require  any  particular  care  during  transport,  however  it  is 
advisable to observe the general guidelines already outlined for storage. 
7. TECHNICAL DETAILS 
  TURBINE 170 ventilation unit 
‐ Air flow rate with different types of filters: 130 l/min; 170 l/min 
The  air  flow  rate  is  stabilised  by  an  anemometric  device  (wind  gauge)  which  regulates  the  speed  of  the  ventilator 
independently from the battery's residual tension, thus optimising the duration. 
‐ Recommended functioning temperature: between ‐20°C and +50°C with U.r. < 80% 
‐ Duration: about 9 hours with a flow rate of 170 l/min and anti‐dust filters, and around 7 hours with a flow rate of 
130 l/min and combined filters 
 Battery pack 
‐ Type: Lithium polymer 
‐ Nominal voltage: 14.8 Volt 
‐ Charging time: about 3.5 hours 
 Battery charger 
‐ Network power: 
 
‐ Frequency: 
 
 
‐ Operating temperature: 
‐ Storage temperature  ‐40  +85 °C 
‐ The red LED indicator indicates the battery is charging, green indicates the battery is charged. 
Masks TR 82 – TR 2002 
Conforming to standard EN 136:98. Refer to specific instructions provided with the product. 
Helmets/Hoods CFU Helmet with visor, FU Light Visor, H Tyvek® Hood F 
Conforming  to  standards  EN  166  and  EN  397  (only  for  the  model  CFU  Helmet  with  visor).  Refer  to  specific 
instructions enclosed with the product. 
8. PRODUCTION AND MARKING DATE  
The CE mark, followed by the identification 0426 of the Notified Organisation (Italcert S.r.l., Viale Sarca, 336 ‐ 20126 
Milano), which has carried out the type tests for the CE certification, and which carries out the production control 
according to Art.11.B D.E. 89/686/EEC, can be found on the label attached to the base of TURBINE 170 (example A). 
The same label displays the devices which the TURBINE 170 is part of, respective standard references and a serial 
number (SN) which is composed as follows: mm (production month) / yyyy (production year) – T‐nnn (progressive 
serial number). A sticker is attached to the battery pack (example B) with the code number and the production date. 
Examples C display the filter labels 100 P3 R, 202 A2B2E2P3 R and 202 A2B2P3 R. 
The year of production is displayed on the breathing tube. 
 
AVERTISSEMENT 
Seul le respect strict des règles du présent manuel peut garantir le bon fonctionnement et une utilisation en toute 
sécurité  des  ventilateurs  à  filtre  TURBINE 170.  SPASCIANI  SPA  décline  toute  responsabilité  pour  tout  dommage 
susceptible de se produire en raison de l'utilisation inadéquate ou erronée des ventilateurs à filtre TURBINE 170, il en 
va de même pour les entretiens ou réparations qui ne sont pas effectués dans les ateliers de l'entreprise ou par des 
tiers  explicitement  approuvés  par  l'entreprise  elle‐même.  Veuillez  noter  que  l'appareil  de  protection  respiratoire 
doit être utilisé par du personnel formé à cet effet et sous la supervision et la responsabilité de personnes qui sont 
parfaitement conscientes des limites de l'application et de la législation en vigueur. 
L'utilisation d'accessoires ou de pièces non d'origine est interdite et annulera la garantie de l'appareil respiratoire. 
100‐240Vac 
 50‐60 Hz 
‐10  +50°C 
FR    MANUEL D'UTILISATION 
 10 / 20 

Publicidad

Tabla de contenido
loading

Tabla de contenido