10. Programming the Receiver Operating Frequency
& High Speed Conditioning of Fan Control
-- Important - Read This Section Carefully and Follow
the High Speed Conditioning Instructions Closely --
IMPORTANT: Ceiling Fan Blades MUST be installed
before High Speed Conditioning can begin.
NOTE: If using a 3-way Switch Installation, ensure
that both Wall Controls are using the same Switch
Code.
10.1
Flip the Wall Control ON/OFF Switch (
"OFF" ( O ) position .
Restore Electricity to the Ceiling Fan Branch Circuit at
the Circuit Breaker or Fuse Box .
Flip the Wall Control ON/OFF Switch to "ON" (
position .
Within one minute of flipping the Switch to "ON", push
and hold the FAN POWER OFF Button (
seconds to set the Code in the Receiver . The Ceiling
Fan Lights (if installed) will blink to indicate the Wall
Control Code has been paired with the Receiver .
IMPORTANT: Immediately after successful pairing,
the Ceiling Fan will automatically begin High Speed
Conditioning of the Motor. During conditioning, the
Electronic Motor Control Software is calculating
Speeds for the 2nd through 5th Speed settings
based on the Blades that were installed on the Fan.
INSTRUCTION TO THE USER (if device contains a digital device)
This equipment has been tested and found to comply with the limits for a class B digital device, pursuant to part 15 of the FCC
Rules . These limits are designed to provide reasonable protection against harmful interference in a residential installation .
This equipment generates, uses and can radiate radio frequency energy and if not installed and used in accordance with the
instructions, may cause harmful interference to radio communications . However, there is no guarantee that interference will not
occur in a particular installation . If this equipment does cause harmful interference to radio or television reception, which can be
determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the
following measures:
• Reorient or relocate the receiving antenna .
• Increase the separation between the equipment and receiver .
• Connect the equipment into an outlet on a circuit different from that to which the receiver is connected .
• Consult the dealer or an experienced radio/TV technician for help .
This equipment has been certified to comply with the limits for a class B computing device, pursuant to FCC Rules. In order to
maintain compliance with FCC regulations, shielded cables must be used with this equipment . Operation with non-approved
equipment or unshielded cables is likely to result in interference to radio and TV reception . The user is cautioned that changes
and modifications made to the equipment without the approval of manufacturer could void the user's authority to operate this
equipment .
This Class B digital apparatus meets all requirements of the Canadian Interference-Causing Equipment Regulations.
10.2
The Fan will run for approximately 1 minute in the
Upward Direction then Reverse Direction to down flow
and run an additional 1 minute . When Conditioning is
complete, the Fan will come to complete stop .
IMPORTANT: Do not interrupt the Conditioning until
the Fan comes to a complete stop in approximately
2 minutes. All functions of the Control will be
) to the
rejected during Conditioning.
High Speed Conditioning is now complete .
10.3
)
If programming is unsuccessful, retry the above
instructions after cycling the Wall Control ON/OFF
Switch to restart the 1 minute programming time period .
) for 3 to 5
10.4
If still unsuccessful, shut OFF the Electricity at the Main
Fuse Box or Circuit Breaker Panel and change the
Wall Control Frequency (Section 8 .2, Page 20) . After
changing the Frequency Settings, repeat instructions
10 .1 - 10 .4 of this section within one minute of restoring
the Electricity .
25
Please contact 1-800-777-4440 for further assistance
U.L. Model No.: CF5300