3. Ceiling Fan Assembly
3.9
The Fan comes with Black and White Wires that are
80" long .
Measure up approximately 6 to 9-inches above top of
Hanger Ball / 6" Downrod Assembly (Figure 9) .
Cut off excess Wires and strip back Insulation 1/2-inch
from end of Wires .
4. How to Hang Your Ceiling Fan
CAUTION
!
To reduce the risk of injury, install the fan so that the
blades are at least 7 ft. (2.1m) above the floor (Figure 10).
WARNING
!
Turning off wall switch is not sufficient. To avoid
possible electrical shock, be sure electricity is turned
off at the main fuse box or circuit breaker panel before
wiring. All wiring must be in accordance with National
and Local codes and the ceiling fan must be properly
grounded as a precaution against possible electrical
shock.
(Continued)
1/2-INCH
6 TO 9
INCHES
Figure 9
AT LEAST
7'
Figure 10
8
BLACK WIRE
WHITE WIRE
HANGER BALL
CEILING
FLOOR
U.L. Model No.: CF5300