2. TRANSPORT AND INSTALLATION.
2.1. TRANSPORT AND PACKAGING
Knocks a nd sudden movements must be a voided when tra nsporting the equipment. In a ny ca se, the pa cka g ing must be
protected from wa ter.
HANDLE THE EQUIPMENT CAREFULLY, IT WILL LAST LONGER !
2.2. ELECTRICAL SUPPLY INSTALLATION.
The electrica l insta lla tion of the equipment ma king up the system must be ca rried out by specia lised personnel a ccording to
the a pplica ble sta nda rds.
The loca tion must fulfill the following conditions:
Pla ce: Dry a nd ventila ted. Fa r enoug h a wa y from the welding a rea in order to prevent the dust ca used by the welding
-
process from getting into the equipment. Never work in the ra in.
The distribution pa nel where the ma chine ha s to be connected must ha ve the following elements, a t lea st:
-
CABLE PLUG
"SCHUKO"
2 P + T 1 6A
CABLE PLUG
"CETAC"
2 P + T 3 2A
The connection to the ma ins is ma de by the input hose. IMPO RTANT! Verify tha t the wire is connected to a plug with a n efficient
ea rth ta p.
If you ha ve specia l equipment, with power supply volta g e other tha n 2 3 0 V, you will find the da ta for defining the necessa ry
electrica l insta lla tion on the equipment cha ra cteristics pla te.
Any supply volta g e tha t is outside the ra ted ma rg in g ives rise to the a ctiva tion of the protection system, preventing the welding
opera tion.
Length
1 5 m
> 1 5 m Up to 5 0 m
ELECTRICAL INSTALLATIONS SHOULD ONLY BE HANDLED BY SPECIALISED PERSONNEL.
BEFORE STARTING THE EQUIPMENT, VERIFY THAT THE ELECTRODE-HOLDER CLAMP IS
DO NOT FORGET TO FIT THE EARTH CONNECTION INTO THE PLUG.
MAKE SURE THE MAINS VOLTAGE AGREES WITH THAT ESTABLISHED IN THE MACHINE.
G ALA 2 0 0 0 MP
SO CKET AND ELECTRICAL PRO TECTIO N DEVICES
SO CKET AND ELECTRICAL PRO TECTIO N DEVICES
G ALA 2 0 0 0 MP
CRO SS-SECTIO N
4 mm
2
6 mm
2
SEPARATED FROM THE WELDING EARTH CLAMP.
SO CKET
MAGN ETOTHERMAL
SWITCH
DIFFERENTIAL
CIRCUIT-BREAKER
SO CKET
MAGN ETOTHERMAL
SWITCH
DIFFERENTIAL
CIRCUIT-BREAKER
If it is necessa ry to use a longer power supply hose or a
connection to a n extension, keep in mind the va lues of this
ta ble. These va lues a re for reference a nd a re influenced by the
sta te of the conductors, connections a nd a mbient tempera ture.
1 7
2 P 1 6A + TT
2 P 1 6A-(2 3 0 V)
2 P 2 5A / 3 0 0 mA
2 P 3 2A + TT
2 P 2 5A-(2 3 0 V)
2 P 2 5A / 3 0 0 mA