Dip switch
AUTOMATIC
1
CLOSING
2
2 / 4 STROKE
CLOSES AGAIN
3
AFTER THE
PHOTOCELL
4
NO REVERSE
PRE-
5
FLASHING
6
FOTOTEST
MASTER/
7
SLAVE
BACK
8
JUMP
9-10-11
Automation type selection
Dip 9
Dip 10
Off
Off
On
Off
Off
On
On
On
Off
Off
On
Off
Off
On
On
On
IMPORTANT: In case the automation type change, a new setting of the dips # 9, 10 and
11 will be required. Before the new setup, however, it is necessary to proceed to a HARD
RESET (see pag. 25) of the controller.
SENSITIVE
12
EDGE
when completely open, closure is automatic after the set time on the
On
T.C.A. trimmer has past.
Off
the closing manoeuvre requires a manual command.
when the automation is operating, a sequence of opening/closing
On
commands causes the automation to OPEN-CLOSE-OPEN-CLOSE, etc.
in the same conditions, the same sequence of commands causes the
Off
automation to OPEN-STOP-CLOSE-STOP-OPEN-STOP, etc . (step-by step
function) (see also dip switch 4).
after the photocell is activated (input 7 - 9), the automation closes au-
On
tomatically after 5 seconds.
Off
function off.
the automation ignores the closure command during opening and
On
auto-close time
Off
the automation responds as established by dip switch No. 2.
On
the pre-flashing function is enabled.
Off
the pre-flashing function is disabled.
On
the "photocell test" function is enabled.
the "photocell test" function is disabled.
Off
Note: to be used when the photocells are not used.
enables the MASTER mode in the master/slave configuration (see T-
On
COMM instructions).
enables the SLAVE mode in the master/slave configuration (see T-
Off
COMM instructions), or standard operation (single motor).
once reached the mechanical stop (either while opening or closing) the
On
operator will reverse slightly to avoid jamming between pinion and rack.
Off
function not activated.
Dip 11 Automation
Off
T-ONE10B For gates up to 400 kg
T-ONE10B For gates from 600 to 1000 kg
Off
Off
T-ONE8BR (24v)
Off
MASTER-R (24V Opening speed = Closing speed)
On
MASTER18QR
On
MASTER-R (24V)
On
T-ONE8BR (24V Opening speed = Closing speed)
On
CANTILEVER TONE10B (heavy)
On
RESISTIVE SENSITIVE EDGE (terminal No. 10).
NC CONTACT SENSITIVE EDGE ( terminal No. 10).
Off
Note: if not used, keep the DIP in the OFF position.