Low Battery Indicator - Arregui Perfect Manual De Instrucciones

Caja fuerte electrónica
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

2.4. ERASING THE USER CODE
• Press «ON».
• Press «ENTER».
• Press «0».
• Press «ENTER».
• PEnter the user code and press "ENTER".
• PEnter the master code and press "ENTER".
The user code will be erased and the master code will be kept.
2.5. PROGRAMMING THE DUAL CODE
When using the dual code system, it is necessary to enter
the master code and the user code to open the safe.
To enable this function, both codes need to first be
programmed.
• Press "ON".
• Press "ENTER".
• Press "7".
• Press "ENTER".
• Enter the current master code and press "ENTER".
2.6. OPENING THE SAFE WITH THE DUAL
CODE FUNCTION
• Press "ON".
• Enter the current master code.
• Press "ENTER".
• The safe will beep and the light will turn green.
• The safe will beep every 5 seconds for the next 60 seconds.
• Enter the current user code and press "ENTER". You have
approximately 5 seconds to turn the handle clockwise and
open the safe.
2.7. DEACTIVATING THE DUAL CODE
• Press "ON".
• Press "ENTER".
• Press "8".
• Press "ENTER".
• Enter the current master code and press "ENTER".
2.8. PROGRAMMING THE OPENING DELAY TIME (OD)
AND THE OPENING WINDOW (OW)
The opening delay time function (OD) refers to the amount of
time that passes between the code is entered and the door is
unlocked (green light).
The opening window (OW) is the period during which you can
open the door once the OD has passed. This is the same when
opening with both the master and the user code..
• Press "ON".
• Press "ENTER".
• Press "6".
• Press "ENTER".
• Enter the current user or master code and press "ENTER".
• Enter a 2-digit number for the opening delay, OD (01-99
minutes), and a 1-digit number for the opening window, OW
(1-9 minutes).
• Press "ENTER".
For example, if you enter 092, the OD will be 9 minutes (how
long you must wait before you can open the safe) and the OW
will be 2 minutes (time available to open the safe).
Opening with OD and OW programmed:
• Press "ON".
• Enter the current user or master code.
• OD automatically starts: red light flashes every 5 seconds.
• OD ends: beep.
• OW automatically starts: green light flashes and beep every
5 seconds.
• Enter the opening code again during the OW.
Once the light turns green you have approximately 5
seconds to turn the handle clockwise and open the safe.
You can interrupt this function by pressing "ENTER" during the
OD period. The whole sequence must be repeated.
Cancelling the programmed OD/OW:
• Press "ON".
• Press "ENTER".
• Press "6".
• Press "ENTER".
• Enter the valid user or master code and press "ENTER".
• Enter "00" as the 2 digits for the OD period (opening delay
time) and "0" as the digit for the OW (opening window).
• Press "ENTER"..
For example, enter "000" to cancel the OD and OW.
2.9. TURN THE SOUND ON/OFF
• Press "ON".
• Press "ENTER".
• Press "5".
• Press "ENTER".
• Enter the current master code and press "ENTER".

3. LOW BATTERY INDICATOR

When the battery is low, the light turns red and the safe will
beep 5 times. In this case, it is necessary to change the
batteries.
En

Publicidad

Tabla de contenido
loading

Tabla de contenido