63
Enables breaking before an inversion (AP–CH o CH–AP)
A
0 → NOT breaking before the inversion
1 → breaking before the inversion
64
Breaking time
A
1-99 → breaking time on DECIMAL SECONDS
65
Breaking force
A
1-8 → LEVEL
71
Motor position on the gate. Change the rotation of the motor for opening and closing and it changes
automatically the limit switch without invert the cables. Whenr You change this parameter You have to
power off and after power on
0 → motor on LEFT looking from inside
1 → motor on RIGHT looking from inside
72
Limit switch. If You do not install the limit switch, You have to fit the mechanical stop
0 → limit switch ON
1 → limit switch OFF or not installed
2 → it is on ONLY the opening limit switch
73
Configuration of safety edge 1, installed on motor side, it is active only in opening and it inverts the motor
only for a few seconds.
0 → safety edge 1 OFF or not installed
1 → safety edge 1 SWITCH type
2 → safety edge 1 RESISTIVE type
3 → safety edge 1 SWITCH type, it always inverts
4 → safety edge 1 RESISTIVE type, it always inverts
74
Configuration of safety edge 2, installed on opposite side of the motor or on the gate and it is active only
in closing and it inverts only for a few seconds i
0 → safety edge 2 OFF or not installed
1 → safety edge 2 SWITCH type
2 → safety edge 2 RESISTIVE type
3 → safety edge 2 SWITCH type, it always inverts
4 → safety edge 2 RESISTIVE type, it always inverts
75
Encoder set up
A
0 → optical encoder
1 → magnetic encoder
76
Configuration of 1° radio receiver channel
A
0 → PP
1 → PEDESTRIAN
2 → OPEN
3 → CLOSE
4 → STOP
5 → COURTESY, the normal functionning is not enable, the relay is only managed by the radio receiver
6 → COURTESY PP, the normal functionning is not enable, the relay is only managed by the radio
receiver. It is like the step by step: on-off-on-off.. the device connected on courtesy light
7 → FLASHING LIGHT, the normal functionning is not enable, the relay is only managed by 1° radio
receiver channel
8 → FLASHING LIGHT PP, the normal functionning is not enable, the relay is only managed by the
radio receiver, it is like the step by step: on-off-on-off.. the device connected on flashing light
77
Configuration of 2° radio receiver channel
A
0 → PP
1 → PEDESTRIAN
2 → OPEN
3 → CLOSE
4 → STOP
5 → COURTESY, the normal functionning is not enable, the relay is only managed by the radio receiver
6 → COURTESY PP, the normal functionning is not enable, the relay is only managed by the radio
receiver. It is like the step by step: on-off-on-off.. the device connected on courtesy light
7 → FLASHING LIGHT, the normal functionning is not enable, the relay is only managed by 2° radio
receiver channel
8 → FLASHING LIGHT PP, the normal functionning is not enable, the relay is only managed by the
radio receiver, it is like the step by step: on-off-on-off.. the device connected on flashing light
78
Output configuration of flashing light
A
0 → FIXED output, it must be the flashing light electronics to make the flashing
1 → 1Hz, the output is on and off 1 time per second (1Hz), the flashing light must be a fixed light
2 → different flashing for opening and closing, the output is on and off 1 time per second (1Hz) in
opening and 2 times per second (2Hz) in closing, the flashing light must be a fixed light
(1 = minimum... 8 = maximum)
14
1
5
8
1
0
0
0
0
0
1
0