Clean/Replace the Diaphragm (cont.)
Rinse any debris from the diaphragm.
NOTE: If required, use a pliers to remove the diaphragm support.
If removed, insert a new diaphragm support ring in the inlet arm.
With the bumpy side facing out from the inlet arm, insert the
new diaphragm.
Thread the inlet arm into the valve body until it reaches the end
of travel. This may require several turns.
Using a 2.5 mm hex key, tighten the setscrew on the inlet arm.
Align the arrows on the connectors, then connect the DC sensor
connector to the solenoid connector.
NOTICE: Ensure that the wires are not caught between the cap and
the valve body.
Place the cap on the valve body and reinstall the hex screw.
Open the control stop valve.
Verify the valve functions.
Kohler Co.