ATTENTION! When proceeding with ignition of the pilot burner, please remember that there is
air in the fitting, which must be displaced by the incoming gas from the supply system. When the
gas has filled the entire stove fitting, the unit actuates.
Turn the knob (counterclockwise) to the full-flame position (Fig. 12) in order to light the main burner
(lit by the pilot burner). Then turn the knob further in the same direction to get an energy-saving flame
(Fig. 13). The main burner will not be actuated if the pilot burner does not light and heat the gas leak
detector. In the event of a temporary fadeaway of flame, the gas leak detector will cut off the gas supply
to the burner.
Figure 12. Setting of the knob in which the burner operate at its maximum power.
Figure 13. Setting of the knob in which the burner operates at its minimum power (about 1/3
If you temporarily do not use the burner, turn the pilot knob to the „pilot burner" position (Fig. 11).
When the burner is not longer in operation, close the gas supply by turning the pilot knob clockwise
to the „closed" position (Fig. 10). Attention! When using LPG, before switching off the burner
with the knob, the cylinder valve must be closed!
4.2.
Oven
Make sure that the oven pilot knob (Fig.1 item 4) is in the „closed burner" position (Fig.14)
Figure 14. Setting of the knob in which the gas supply to the oven burner is completely cut
Open the valve of the LPG cylinder equipped with a regulator having the output pressure acc. to the
unit's nameplate (only in case of LPG-powered stoves).
Open the oven door
Press the knob controlling the oven burner (Fig.1 item 4).
Turn and hold the knob in the pilot burner position (Fig. 15).
of the maximum power).
off.