Press and hold both icons
for 2 seconds.
+
Temperature – Set the Default
IMPORTANT! For systems with both a bath filler and shower: When setting the default temperature, set
the default for comfortable showering; adjust your desired bathing temperature manually as needed.
This setting allows you to set the temperature the shower will be set to at initial start-up.
Factory default for this setting is the limit specified in program 7, up to 100°F (37.8°C). The minimum
temperature setting is 86°F (30°C).
NOTE: The maximum temperature setting is the limit specified in program 7, up to 120°F (48.9°C).
Press and hold the [Power Icon] and the [Up Icon] to enter the settings menu. If your shower is on,
the water will be shut off.
Use the [Up Icon] or [Down Icon], to step to the "Prog 6" screen. Press the [Power Icon].
Use the [Up Icon] or [Down Icon] to set the desired default temperature. Press the [Power Icon] to
set.
Press the [Power Icon] again to return to the settings menu.
Continue Set-up: Use the [Up Icon] or [Down Icon], to choose the next desired setting; press the
[Power Icon] to select. See the section for the chosen setting.
To Exit the Settings Menu: Use the [Up Icon] or [Down Icon], to step to the "Prog En" screen and
press the [Power Icon]. The system will go into standby mode.
Kohler Co.
Set your preferred default
temperature.
13
1144502-5-D