The Vess R2600 or Vess J2600 installs to the rack using the mounting rails shipped with the device.
Note
To lighten the Vess R2600 or Vess J2600 enclosure, you can remove the power supplies. Replace the power
supplies after the Vess R2600 or Vess J2600 unit is mounted in your rack.
To install the Vess R2600 subsystem or Vess J2600 expansion into a rack with the supplied mounting rails:
1. Check the fit of the mounting rails in your rack system.
2. Adjust the length of the mounting rails as needed.
• The rear rail slides inside the front rail. The rail halves are riveted together and use no adjustment screws.
• The front-left and front-right mounting rail ends are labeled.
• Be sure the front rail support is on the bottom facing inward.
Figure 6: Installing the rails onto the rack
Support flange on the front
end of each rail
• All rail ends, front and rear, attach at the outside of the rack posts.
• The guide pins at the rail ends align with the holes in the rack posts.
• Use the attaching screws and flange nuts from your rack system. Tighten the screws and nuts according to instructions for
your rack system.
Figure 7: Rail ends attach to the outside of each post
3. Place the Vess R2600 or Vess J2600 onto the rails.
• At least two persons are required to safely lift the subsystem.
• Lift the Vess R2600 or Vess J2600 itself. Do not lift the subsystem by its brackets.
Front left label
Rail ends attach on the
outside of the front and
rear rack posts
Front right label
Guide pins on rails align with
holes in the rack post
7