Preparation
Important Safety Instructions
This unit has a polarized plug (one blade is wider than the other) as a safety feature. This plug
will fit in a polarized outlet only one way. If the plug does not fit fully into the outlet, reverse the
plug. If it still does not fit, contact a qualified electrician. Never use with an extension cord
unless plug can be fully inserted. Do NOT attempt to defeat this feature.
Please read and understand this entire manual before attempting to assemble, operate or
install the product. SAVE THESE INSTRUCTIONS.
INSTRUCTIONS PERTAINING TO A RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS.
IMPORTANT SAFETY INSTRUCTIONS.
1. Electrical Ratings: 120VAC, 60Hz; Watts per bulb .05 one bulb per 1"
2. Fuse Replacement Ratings: 125V, 5A
3. Do NOT cover this product as the covering may cause the rope light to overheat, and
melt, or ignite.
4. Do NOT operate the Flexolight tightly coiled.
5. Do NOT route the Flexolight, or cord through walls, doors, windows, or any like part of the
building structure.
6. Ensure all connections and the end cap on the last segment is tightly secured to preclude the
entry of water.
7. Do NOT subject Flexolight to continued flexing.
8. Do NOT exceed the length in feet permitted by the marking.
9. Do NOT puncture, cut, shorten, or splice the Flexolight lighting.
10. Do NOT use if there is any damage to the Flexolight, or cord insulation. Inspect periodically.
11. Do NOT submerge Flexolight in liquids, or use the product in the vicinity of standing water, or
other liquids. Secure the Flexolight cable using only the hangers or clips provided.
12. Do NOT secure this product or it's cord with staples, nails, or like means that may damage the
insulation.
13. Use only extension segments provided by supplier.
14. Do NOT cut or splice Flexolight. Flexolight can only be extended by using the optional
extension connector. Use ONLY the Flexolight extension connector for extending your
Flexolight rope lights.
15. CAUTION: California Prop. 65 Warning: Handling the coated electrical wire inside the rope light
can expose you to lead, a chemical known to the State of California to cause cancer,
birth defects, and other reproductive harm. You should thoroughly wash your hands if
you have come into contact with the internal coated wires in this product.
16. Do NOT leave Flexolight on when unattended. Your Flexolight rope lighting does get HOT
and must be installed in areas having good air circulation.
17. The outer surface of your Flexolight rope lighting may become hot after being left on for
an extended period of time. Allow sufficient time for the Flexolight to cool down prior to
handling the rope light.
18. Do NOT attempt to replace the lamps used in Flexolight. The lamps are NOT replaceable.
19. Use caution when installing Flexolight in areas accessible to children. Flexolight should
not be used around children under 6 years of age minimum.
20. If Flexolight is installed outdoors, you MUST use a Ground Fault Interrupting Circuit
(GFCI) outlet or contact a qualified electrician to do your installation.
21. Periodic inspections of your Flexolight are important. Any sections of the Flexolight that
appear damaged, or have any of the internal wires protruding, or frayed should be
immediately disposed of. Do NOT operate your Flexolight if any of these conditions are
present.
22. Do NOT mount Flexolight over any sharp edges that can cut the plastic outer tubing.
23. Do NOT place Flexolight near areas having standing water, or running water such as pools, spas,
saunas, fountains, or the like. Flexolight is intended for outdoor installations that are either above
ground level, or areas that are well drained of water. Do NOT install, or submerge Flexolight under
water.
24. Do NOT install Flexolight near flammable materials (i.e. curtains, drapes, etc.), or materials
that may melt (i.e. carpeting, plastics, etc.) from the heat generated by the Flexolight rope
lighting.
25. NEVER glue, nail, or staple Flexolight directly onto any surface. Use ONLY the mounting clips,
and tie straps provided in the installation kit for securing your Flexolight.
26. Do NOT hang any objects from the Flexolight.
27. Do NOT overload the power outlet. Refer to the loading label/marking on the Flexolight.
28. Do NOT install Flexolight into any enclosure, or areas that limit air circulation. Your Flexolight
should always be installed where there is adequate ventilation.
29. Do NOT attempt to install in-line cord switches if using Flexolight outdoors.
30. Do NOT exceed a total of 300ft. of connected rope lights.
WARNING: When using outdoor use portable lighting products, basic safety precautions should
always be followed to reduce the risk of fire, electric shock, and personal injury, including the
following:
(a) Ground Fault Circuit Interrupter (GFCI) protection should be provided on the circuits or
outlet to be used for the outdoor use flexible lighting product. Receptacles are
available having built-in GFCI protection for this measure of safety.
(b) Use only outdoor extension cords, such as type SW, SOW, STW, STOW, SJW, SJOW,
SJTW, or SJTOW. This designation is marked on the wire of the extension cord.
DO NOT ATTEMPT TO ASSEMBLE THIS LAMP WHILE IT IS PLUGGED IN. Do NOT plug Flexolight
into a power source UNLESS the following conditions have been met:
1
You have completely uncoiled Flexolight to avoid
damage from excess heat. The end sealing cap, and
line cord are securely attached to the rope light body.
- 2 -