3.4.4 Saving Library Data in Another Location (Cont.)
Press the Enter button to save data.
UPDATE DONE, then the ID number with IN USE will
be displayed momentarily followed by the counting
display.
At this point, all data from Library 22 has been copied
into Library location 52.

3.4.5 Using the Library

To enter the Library, momentarily press the LIBRARY Save button. Use the keypad or the M+ button to enter a location
ID that you wish to use. Press the LIBRARY Save button again to select the new ID. ID XX IN USE will display indicating
that the data stored in that memory is now active. If an APW and a Preset Tare was set, placing a sample filled
container on the scale will give an immediate count.
If the Library is not locked, it is possible to edit the data in the current ID. The changes need not be saved if they were
for temporary use. If the Library is locked, you must change to ID 00 for simple counting use.

3.5 Auto Optimization

Automatic reference optimization results in a more accurate count by increasing the reference weight without the need
to count additional parts. A higher reference weight is important when there is a risk of inconsistent piece weights or if
the reference weight is close to the minimum (See section 7.1).
Auto Optimization uses an initial APW to count additional pieces that are placed on the scale. After a few seconds, the
message A-OPt appears in the Data display as the new higher reference weight is used to re-calculate the APW. The
process can be repeated as long as the additional weight is less than the previous reference weight. Once this limit is
exceeded Auto-Opt is turned off. This function can be activated or deactivated in the Count menu. The factory default
setting is on.

3.6 Auto Add Mode

Auto Add Mode is setup for a more accurate count procedure by increasing the minimum reference weight and the
minimum APW limits (see section 7.1). The scale requests additional pieces if the reference weight is less than the
recommended Auto-Add minimum weight in Table 7-2. The instructions to add these additional pieces may be ig-
nored. This function can be activated or deactivated in the Count menu. The factory default setting is off.
Place the stipulated number of pieces on the scale
(e.g. 2 pieces). The scale then determines the new
APW based on the total pieces
WEIGHT
kg
g
lb
oz
Net
B/G %Ac
WEIGHT
kg
g
lb
oz
Net
B/G %Ac
WEIGHT
kg
g
lb
oz
B/G %Ac
Net
WEIGHT
kg
g
lb
oz
Net
B/G %Ac
Trooper Count Scale
DATA
COUNT
<
T
PT APW MR
M
BLINKING
DATA
COUNT
<
T
PT APW MR
M
DATA
COUNT
<
T
PT APW MR
M
DATA
COUNT
<
T
PT APW MR
M
>
PCS
>
PCS
>
PCS
>
PCS

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Tc6rsTc15rsTc30rsTrooper count

Tabla de contenido