Simer Ace-In-The-Hole A5000-01 Manual Del Usuario página 4

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Installation
2. Unplug the pump. See Figure 1.
3. Unclamp any cords from the discharge pipe.
4. Locate the "on" water level of the primary sump
pump. Mark this location on the discharge pipe with
a pencil. See Figure 1.
Loosen the pump
cords from
the discharge
Support the
pipe by removing
exterior dis-
the clamps.
charge pipe.
Separate
or cut
pipe here.
Check
Valve
Primary
Sump Pump
14" Minimum Sump Diameter
Figure 1 – Installation Diagram.
5. To separate the primary pump from the discharge
pipe:
A. For applications with rubber couplings: remove
the coupling clamp with a nut driver.
B. For applications without rubber couplings: cut the
PVC discharge pipe with a hacksaw above the
basement floor and at a comfortable level. New
rubber couplings are included for reassembly.
Risk of pinching hands or fingers. To avoid
a hand injury from a collapse of plumbing, support the
pipe above the separation before cutting or disassembly.
6. Lift the primary pump and discharge pipe assembly
out of the sump. See Figure 2.
Risk of electrical shock. Shock can burn or
kill. Do not lift the pump by the electrical cord; lift pump
only by the discharge pipe, lifting ring or handle on the
pump. Lifting by the cord can damage the cord.
For parts or assistance, call Simer Customer Service at
Unplug the
sump pump.
Primary pump
float switch in
ON position.
Locate and
mark the "On"
water level of
primary sump
pump on the
discharge pipe.
Figure 2 - Back-up pump location and assembly.
INSTALL BACKUP PUMP
injury and flooding. Do not turn the pump on until all
the fittings are glued and the glue has dried. Loose fit-
tings can explode off of pipes and cause personal injury
and flooding.
NOTICE: This pump is intended for use in sumps with a
14" or larger diameter. For 9" - 14" diameter sumps,
order Switch Kit number SSSA.
1. Mark the back-up pump location - on the primary
pump discharge pipe 1" above the "ON" water level
of your primary sump pump. The bottom of the
back-up pump should be no lower than this mark
when finished. See Figure 2.
2. Remove the U-bolt clamps and nuts from the parts
bag.
1-800-468-7867 / 1-800-546-7867
Backup Pump and
Check Valve
Assembly
Double clamped
mounting on the
primary pump's
discharge pipe.
Make the
second
mark here.
1"
Previously
marked
water line.
Primary Pump
Discharge Pipe
Not to Scale
Switches and
Wiring omitted
for clarity
Risk of explosion. Can cause personal
4
Hose Coupling
with Clamps
Check Valve
The bottom of
back-up sump
pump is located
1" above the
previously
marked
water line.
4328 0203

Publicidad

Tabla de contenido
loading

Tabla de contenido