Electrical
TABLE I – WIRING CONNECTIONS
Connect the ...
To ...
1. Control Box Panel
the Battery
2. Back-up Pump
the Pump Connection in the
Power Cord
Control Panel
3. Float Switch
the Float Switch Socket in the
Connector
Control Panel
4. Transformer from
the Transformer Socket in the
Wall Outlet
Control Panel
TABLE II – CHARGING ERRORS
All lights flashing
at a rate of once
per second
with Alarm on
All lights flashing
at a rate of once
per second
with the Yellow
(Charging/AC Power)
light and Alarm on
TABLE IV – CAPACITY RATINGS WITH A 12 VOLT (27M MARINE BATTERY)
Flow Rate (gallons per hour)*
* These flow rates were obtained with a constant 12.7 VDC battery source. The average GPH will vary due to a reduction in
output voltage from battery.
For parts or assistance, call Simer Customer Service at
Blown fuse.
Battery leads are reversed.
Incorrect battery (not 12V).
Battery is taking too long to
charge. May need to replace
battery.
Battery in thermal runaway.
Replace battery.
Battery charge is too low
(below 8.2V). The system
will not allow the pump
to run.
VERTICAL PUMPING DISTANCE (FEET)
0
5
1380
1200
TABLE III – CONTROL PANEL/LIGHTS
& ALARM SUMMARY
Green (Ready) Light
is on
Green Light is
Flashing while the
Alarm is beeping
Yellow (Charging/
AC Power) Light
is on
Yellow Light
is Flashing
Red (Pump Cycled)
Light is on with
alarm on
Red (Pump Cycled)
light is Flashing while
the Alarm is beeping
Red (Alarm Off)
Light is on
ALL LIGHTS SECTION
All lights on for
3 seconds
All lights and
alarm are on
All lights flashing
at a rate of once
per second with
the yellow light
and alarm on
All lights flashing
at a rate of once
per second with
the alarm on
10
15
1080
840
1-800-468-7867 / 1-800-546-7867
Battery is fully charged and
system is ready.
Battery charge is below 10.9V.
NOTICE: Pump may not run
while battery is charging.
Battery is being charged.
Battery or AC power wires
are not connected.
Pump is running. Normal
back up system operation.
System activated by the
float switch.
Pump has run.
The alarm is turned off.
System is resetting.
"Test Pump" button is on.
User is testing the pump.
See Table II,
Charging Errors.
See Table II,
Charging Errors.
20
25
600
360
7
30
60