3. TECHNICAL CHARACTERISTICS
3.1. REFERENCE CONDITIONS
Quantity of influence
Temperature
Relative Humidity
Supply voltage
Frequency of the measured signal
3.2. ELECTRICAL CHARACTERISTICS
Maximum current: 13 Aac (no DC)
Max. charging power: 2,9 kVA
Maximum current in the mains connector: 10 A
The mains connector is protected against overloads by a fuse.
Type 2 connector: 32A, 3PH+N+PE, type E-2201, 200/346V-240/415V
3.3. POWER SUPPLY
The CA 6651 is supplied by the charging terminal being tested via the type 2 connector.
3.4. ENVIRONMENTAL CONDITIONS
For indoor use, outdoor use without rain.
Domain of use
Storage
Pollution degree
Altitude
3.5. CONSTRUCTION CHARACTERISTICS
Dimensions of the housing (L x W x H) 150 x 83 x 77mm
Dimensions of the type 2 connector
Length of the cable
Weight
Protection index
0 to 40°C, 80% RH without condensation
-10 to 50°C, 80%RH without condensation
2.
<2,000m.
208 x 58 x 51mm
approximately 53cm
approximately 830g
IP20 per IEC 60529.
Reference values
23±5°C
20 to 75%RH
230 V single-phase
400 V three-phase
50Hz
31