Emergency manual manoeuvre
(for model E MH / E LH only)
The model E MH / E LH is equipped with a mechanism
fitted in the motor head (fig. 7-f) which enables the us-
er to make an emergency manual manoeuvre by rotating
the rod in one direction or the other. To avoid premature
wear of the mechanism, it should be used exclusively in the
event of an emergency, such as a power failure.
CAUTION! – During this emergency manoeuvre, the
shutter must NOT exceed the travel limits "0" and "1"
set during product installation.
Product disposal
This product is an integral part of the automation and
therefore must be disposed together with the latter.
As in installation, also at the end of product lifetime, the
disassembly and scrapping operations must be performed
by qualified personnel. This product comprises various
types of materials: some may be recycled others must be
disposed of. Seek information on the recycling and dispos-
al systems envisaged by the local regulations in your area
for this product category. Caution! – some parts of the
product may contain pollutant or hazardous substances
which, if disposed of into the environment, may cause seri-
ous damage to the environment or physical health. As indi-
cated by the symbol alongside, disposal of this
product in domestic waste is strictly prohibited.
Separate the waste into categories for disposal,
according to the me thods envisaged by current
legislation in your area, or return the product to the retailer
when purchasing a new version. Caution! – Local legisla-
tion may envisage serious fines in the event of abusive dis-
posal of this product.
l The product packaging material must be disposed of in
full observance of current local legislation governing waste
disposal.
What to do if...
(troubleshooting guide)
The motor doesn't move even if powered the Ascent
or Descent phase:
1) check whether a thermal cut-out has tripped: In this
case wait for the motor to cool;
2) check that the mains power is ON and that it corre-
sponds to the values on the motor dataplate.
3) check whether the two limit switches, due to incorrect
settings, engage at the same time; in this case rotate
the two adjustment screws through a few turns, in the
direction of the "+" sign.
After these checks, if the motor still does not move,
contact a specialist technician or the Nice Assistance
Service.
Technical specifications
l Power supply voltage and frequency; current and
power; torque and speed: Consult data on the motor
dataplate.
l Motor diameter: size "S" (Ø 35 mm); size "M" (Ø 45
mm); size "L" (Ø 58 mm).
l Continuous operation time: 4 minutes (maximum).
l Protection rating: IP 44 (tubular motor).
l Minimum operating temperature: -20°C.
l Connection cable length: 2.5 m.
Notes:
- All technical specifications stated in this section refer to
an ambient temperature of 20°C (± 5°C).
- Nice reserves the right to apply modifications to the
product at any time when deemed necessary, maintain-
ing the same intended use and functionality.
EC declaration of conformity
Declaration number: 455/Era-Era Zero
Nice S.p.A. hereby declares that the products:
E S(...), E M(...), E MH(...), E L(...), E LH(...), E Z
M(...), comply with the essential requirements and
other relevant provisions as established by the direc-
tives 2006/95/CE, 2004/108/CE and 1999/5/EC (ap-
plicable only to products with on-board receiver).
The CE declaration of conformity can be consulted
and printed out at the web site www.nice-ser vice.
com or may be requested from Nice S.p.A.
Ing. Mauro Sordini
(Chief Executive Officer)