TECHNICAL INFORMATION
Performance Data Sheet
Carbamazepine
Meprobamate
NSF/ANSI 401
Trimethoprim
Emerging
Contaminants
Metolachlor
While testing was performed under laboratory
conditions, actual performance may vary.

GENERAL OPERATING INFORMATION

Rated Capacity
Min-Max
Operating Pressure
Min-Max Feed
Water Temperature
Rated Service Flow
Daily Water
Production Rate
Product Efficiency Rating
• Do not use with water that is microbiologically unsafe
or of unknown quality without adequate disinfection
before or after the system.
• Refer to the owners manual for specific installation
instructions, manufacturer's limited warranty, user
responsibility, and parts and service availibility.
• The influent water to the system shall include the
following characteristics:
-No organic solvents
-Chlorine: < 2 mg/L
-pH: 7 – 8
-Temperature: 41 - 95°F
(5 - 35°C)
• Systems certified for cyst reduction may be used on
disinfected waters that may contain filterable cysts.
• For parts and service availability, please contact
Brondell at 888-542-3355.
• The compounds certified under NSF/ANSI 401 have
been deemed as "incidental contaminants/emerging
compounds". Incidental contaminants are those
compounds that have been detected in drinking
water supplies at trace levels. While occurring at only
trace levels, these compounds can affect the public
acceptance/perception of drinking water quality.
26
Average
Percent
Substance
Reduction
97.0%
Linuron
93.0%
95.0%
Phenytoin
95.0%
96.0%
DEET
99.0%
100.0%
TCEP
100.0%
TCPP
100.0%
300 gallons (1135.6 L)
35 - 100 psi
(241 kPa – 689 kPa)
39°F – 100°F (4°- 38°C)
0.5 gpm (1.89 lpm)
21.9 gpd (82.9 lpd)
29.1%
-Iron: < 2 mg/L
-Turbidity: < 1 NTU
-Hardness: < 1,000 mg/L
Maximum Permissible Product
Influent Challenge
Water Concentration or Minimum
Concentration
(Mg/L Unless Specified)
1,400 ± 20%
140 ± 20%
400 ± 20%
200 ± 20%
140 ± 20%
1,400 ± 20%
1,400 ± 20%
5,000 ± 20%
5,000 ± 20%
This system has been tested for the treatment of water
containing pentavalent arsenic (also known as As(V),
As(+5), or arsenate) at concentrations of 0.050 mg/L
or less. This system reduces pentavalent arsenic, but
may not remove other forms of arsenic. This system is
to be used on water supplies containing a detectable
free chlorine residual at the system inlet or on water
supplies that have been demonstrated to contain
only pentavalent arsenic. Treatment with chloramines
(combined chlorine) is not sufficient to ensure
complete conversion of trivalent arsenic to pentavalent
arsenic. Please see the Arsenic Facts section of this
Performance Data Sheet for further information.
Efficiency rating means the percentage of the influent
water to the system that is available to the user
as reverse osmosis treated water under operating
conditions that approximate typical daily usage.
The product water should be tested every 6 months
to ensure that the contaminants are being reduced
effectively. For any questions, please contact Brondell
toll free at 888-542-3355.
This reverse osmosis system contains replaceable
treatment components critical for the effective
reduction of total dissolved solids, and that product
water shall be tested periodically to verify that the
system is performing properly. Replacement of reverse
osmosis component should be with one of identical
specifications, as defined by the manufacturer, to
assure the same efficiency and contaminant reduction
performance.
The estimated replacement time of filter, which is
a consumable part, is not an indication of quality
guarantee period, but it means the ideal time of filter
replacement. Accordingly, the estimated time of filter
replacement may be shortened in case it is used in an
area of poor water quality.
System and installation shall comply with all state and
local regulations.
Allowable % Reduction
(mg/L unless specified)
200 ng/L
20 ng/L
60 ng/L
30 ng/L
20 ng/L
200 ng/L
200 ng/L
700 ng/L
700 ng/L