PRODUCT INSTALLATION
Step 1: T-Valve Installation
DO NOT INSTALL THE FILTER HEAD CONNECTION ASSEMBLY FURTHER THAN 12 FEET
AWAY FROM EITHER THE WATER SUPPLY VALVE OR THE INDICATOR FAUCET.
Avoid unnecessary slack in the supply hoses when connecting to the water supply, Filter
Head Connection Assembly, or Indicator Faucet. Do not install in direct sunlight or a place
where it will be directly exposed to freezing temperatures.
NOTE: Be sure to install the T-Valve on the cold water supply line.
Running hot water through the Capella will damage the filters.
1. Close the cold-water supply valve. Place a bucket or similar
item underneath the valve to catch any water that may spill out
during installation.
2. Unscrew the hose that connects the cold-water supply valve to
the existing tap water faucet.
3. Ensure the rubber washer is inside the T-Valve Adapter, and
then screw the adapter onto the cold-water supply valve.
NOTE: If the water supply valve is larger than the 3/8" connection on the
T-valve, use the included 1/2" Valve Adapters with Rubber Washers to
connect the T-valve and the water supply hose.
4. Screw the cold-water supply hose to the top of the T-valve closed.
Step 1
Step 3
Step 4
7