Putting Into Operation - Cross Tools CPG 5500 NEV Instrucciones Para El Manejo

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

Translation of the original operating instructions
To fit the wheels (fig. 4, no. 5), first slide the wheel axle (fig. 4, no. 5a) through the holders on
the underside of the generator and fit the wheels as shown in fig. 4. The washers must be fit-
ted on the inside and on the outside. Fasten the wheels in place with the split pins provided.
5
Turn the handles towards you and pull upwards until the latching lug latches into the hole in
the guide
If the generator is to be used for an extended period of time in one place, it is recommended
to fold the handles back into the frame. To do so, press the latching lug and turn the handle
towards the generator.

6. Putting into operation

The generator is equipped with a low-oil safety feature. This convenient technology automat-
ically stops the engine when the engine oil falls below the required minimum level. Because
the generator is delivered without operating materials, it is essential that it is filled with engine
oil before first use. The engine can be started only when a
sufficient quantity of the oil has been filled. When filling with
the operating materials, observe all of the relevant instruc-
tions and specifications cited in these operating instructions.
6.1.
Tests before start-up
Check the battery connection
Before start-up, the "- terminal" of the battery must be con-
nected. Otherwise, it is not possible to operate the genera-
tor. The "+ terminal" is already connected and insulated using a terminal cover.
Note:
When connecting the terminals, first connect the "+ terminal" and then the "-
terminal".
When disconnecting the terminals, first disconnect the "- terminal" and then
the "+ terminal".
Check the engine oil level
Note:Always switch the engine off before checking the engine oil level.
Use a suitable 4-stroke oil for diesel engines. The use of SAE 10W-30 is recommended for
general use in different temperature ranges. The other viscosities stated in the table can be
used if the average temperature in the area of application lies in the stated range.
Screw the support feet onto the bottom frame bars
(fig. 5).
8