Cross Tools CPG 5500 NEV Instrucciones Para El Manejo página 30

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

Check the oil level
1. Remove the oil filler screw and clean the dipstick using a clean cloth.
2. Insert the filler plug with dipstick back into the oil filler port (fig. 8. B) without turning it.
Take the dipstick out again and check the oil level.
3. If the oil level is below the bottom end of the dipstick (min.) add engine oil until the oil
reaches the top mark (max.).
4. Insert the dipstick correctly and screw it on again.
Check the fuel level
1. Check the fuel gauge (fig. 10 no. 3) and fill the fuel tank if the fuel level is too low.
2. Use only Petrol or E10, Diesel can damage the generator considerably.
3. Remove the tank cap (fig. 10 no. 2)
4. Fill with fuel to a maximum level of the bottom of the filter insert (fig. 11, no. 23).
5. Close the tank cap.
10
Earth the generator before use
Make sure that the generator is earthed by pushing a metal rod* into the ground and con-
necting it with earth connection via a cable*. (* = not included in scope of delivery.)
6.2.
Starting the engine with the E-starter
1. Disconnect all consumers from the power supply (.fig. 14, no.17, 18 & 19)
2. Set the fuel cock at the fuel filter to "open" ("ON"). Please see figure 12.
3. Set the choke lever to (fig.13) "Pulled" ("1").
4. Turn the ignition key switch (fig. 13) to "1".
After you perform this step, you can now start the generator.