en - Technical data
Voltage
1
Fuse rating
Roller length
Roller diameter
Type of heating
Overall machine dimensions
Minimum wall distance, lateral
Minimum wall distance, rear
Net weight
Max. load bearing in operation
Total connected load
Heater rating, electric
Connected load, roller
Connected load, fan
2
Electrical connection
Exhaust socket
Ironing throughput according to DIN
3
11902
Roller
Fan air output
Max. permitted pressure loss
Material
Roller padding
Roller cover
Largest removable part
Heat dissipation rate to installation site
Sound pressure level
Sound power level
1
2
Operating class: gG;
Minimum cross-section according to VDE 0298-4;
Granted test certificate: VDE, see data plate; applied product safety standards: IEC/EN 60204-1, IEC/EN 60335-1, IEC/EN 60335-2-44,
EN ISO 10472-1, EN ISO 10472-5
34
PRI 217 EL D 3NAC 400V 50-60Hz STW
Width
Depth
Height
rpm
Outer circumference lin-
ear speed
Contact pressure
Side columns
Roller
Heater plate
3
At 100% occupation + 25% residual moisture
3N AC 400V 50-60Hz
3 x 25 A
1660 mm
250 mm
Electric
2233 mm
651 mm
1110 mm
600 mm
600 mm
189 kg
1890 N
11.6 kW
11 kW
0.4 kW
0.11 kW
5 x 2.5 mm²
70 mm
60 kg/h
1.9 - 5.7 rpm
1.5 - 4.5 m/min
0.5 N/cm²
115 m³/h
100 Pa
Stove-finished, galvanized sheet steel
Galvanized sheet steel
Aluminium, hard-anodised
Wire wool
Polyester needle felt with aramid needle felt cloth
Laundry outfeed table
11 MJ/h
54 dB (A)
59.7 dB