2.

OPERATING THE JABLOTRON 100

The security system can be controlled in a number of different ways. To unset the alarm, authorization
in the form of user identifi cation is always required. The system detects the identity of the users and
allows them to operate those parts of the system which they have been assigned to control. You can
choose from different ways of setting with or without authorization. When Standard authorization type
is used, you don't have to authorize yourself because it is possible to set the system just by pressing
the right segment button on a keypad. The user name, date, and time are recorded and stored in the
system memory every time the system is accessed. This information is available indefi nitely. Any user
can also cancel a triggered alarm (stop sirens from sounding) just by authorization in any part of the
system (depending on their access rights). However, that does not automatically unset the system
(unless the system's default setting is changed).
Note: Depending on the configuration of the installation and system settings, some of the
options described below may not be available. Consult the configuration of the installation
with your service technician.
Users and their access rights
CODE
TYPE DESCRIPTION
AUTHORIZATION
This code has the highest level of authorization to configure the system's behavior and
is exclusively allowed to perform the system unblock after a triggered alarm. It can enter
Service mode, access all tabs with options including ARC communication to which it can
deny access to a Service technician (Service code). As long as the "Administrator-restric-
ted Service/ARC right" parameter remains unchecked, the ARC code can control all sec-
ARC code
tions and PG outputs used in the system. This code enables to add more Administrators
and other users with a lower level of authorization assign them with codes, RFID tags and
cards. It also has a permission to erase alarm and tamper alarm memory.
The number of ARC codes is limited only by remaining capacity of the control
panel and there is no code set by the factory defaults.
This code can enter Service mode and configure the system's behavior. It has access to
all tabs with options including ARC communication unless the access is limited by the
ARC technician. As long as the "Administrator-restricted Service/ARC right" parameter
remains unchecked, the Service code can control all sections and PG outputs used in
the system. It can create users with ARC permission, other Service technicians, Admini-
Service code
strators and other users with a lower level of authorization and assign them with access
(Service)
codes, RFID tags and cards. It also has a permission to erase alarm and tamper alarm
memory. The number of Service codes is limited only by remaining capacity of the control
panel.
By the factory defaults, the code is 1010. The Service user is always on positi-
on 0 in the control panel and it cannot be erased.
This code has always full access to all sections and is authorized to control all PG out-
puts. The Administrator can create other Administrator and other codes with a lower level
of authorization and assign them with access to sections and PG outputs, access codes,
RFID chips and cards. This code has permission to erase the alarm memory. There can
Administrator
be only one main Administrator code which can't be erased. When "Administrator-restric-
code
ted Service/ARC right" is enabled, the administrator code must be authorized to confirm
(Main)
access for ARC and Service technicians.
By the factory defaults, the code is 1234. The main Administrator user is al-
ways on position 1 and it cannot be erased.
This code has access to sections selected by the main Administrator to which the other
Administrator can add new users with the same or lower level of authorization to control sec-
tions and PG outputs, assign them with access codes, RFID tags and cards. This code has
Administrator
permission to erase the alarm memory in assigned sections. When "Administrator-restricted
code
Service/ARC right" is enabled, the administrator code must be authorized to confirm access
(Other)
for ARC and Service technicians. The number of Administrator codes (other) is limited only by
remaining capacity of the control panel.
There is no code set by the factory defaults.
+