When unsetting the alarm using the segment
buttons,
user authorization is always required. When setting
the alarm and controlling automated processes
using the segment buttons, user authorization is
optional for each segment.
Recommended contactless chips: JABLOTRON 100
with 125 kHz EM. If higher security is required the alarm system can be set up to use confi rmed
authorization using RFID chips and codes (optional). If the users want to control multiple segments
simultaneously, they must authorize themselves and then press segments of the particular sections
subsequently. This way the users can for example set the house and unset the garage within one
single authorization. If the "Code with a prefi x" parameter is enabled, the keypad authorization code can
consist of up to eleven digits: a prefi x (one to three digits), an asterisk * (which separates the prefi x and
main code), and a 4,6 or 8-digit code depending on confi guration (for example: 123*12345678, or
1*12345678). All users can change their own codes which follow the prefi x. The code can be changed
from the keypad with the LCD display, the J-Link software or MyJABLOTRON app.
If the "Code with a prefi x" parameter is enabled, the users can be allowed to change their code.
If the "Code with a prefi x" parameter is disabled, the codes can be changed only by the Administrator.
2.1.2. KEYPAD CODE AUTHORIZATION
Authorization with a user code is done by typing a valid code into a keypad or with an RFID tag.
It is possible to use
4, 6 or 8-digit codes
The system can be confi gured to be used with prefi x codes or without them (default settings). For alarm
systems with a higher number of users the prefi x can be enabled. To change this option, please contact the
service technician of your alarm system.
Code without a prefi x:
where:
cccc
is a 4, 6 or 8-digit code, allowed codes are from 0000 to 99999999
Default control panel code
Users can authorize
themselves by entering their assigned codes or using
their RFID cards/tags. Each user can have one code and
up to two RFID chips (cards or tags).
in the system.
cccc
Administrator:
+
, Oasis or other third-party chips compatible
1234; 123456; 12345678
;
EN
29