Machine Setup - Enerpac QuickFace FF-120 Hoja De Instrucciones

Rectificadora de bridas
Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 51
QuickFace Flange Facer

Machine Setup

1. Use a scale to measure the ID of the work piece.
Use the following charts to determine which locator
size is required and the corresponding O-ring.
Locator Size (A)
0.165 in.
#1
(4.2 mm)
0.265 in.
#2
(6.7 mm)
0.365 in.
#3
(9.3 mm)
0.465 in.
#4
(11.8 mm)
0.565 in.
#5
(14.4 mm)
0.665 in.
#6
(16.9 mm)
0.765 in.
#7
(19.4 mm)
0.865 in.
#8
(22 mm)
0.965 in.
#9
(24.5 mm)
1.065 in.
#10
(27.1 mm)
Locator Size (A)
+0.8 in. (+20.3 mm)
Extension
1.065 in.
#2
(27.1 mm)
1.165 in.
#3
(29.6 mm)
1.265 in.
#4
(32.1 mm)
1.365 in.
#5
(34.7 mm)
1.465 in.
#6
(37.2 mm)
1.565 in.
#7
(39.8 mm)
1.665 in.
#8
(42.3 mm)
1.765 in.
#9
(44.8 mm)
1.865 in.
#10
(47.4 mm)
6
ID Min
ID Max
0.96 in.
1.21 in.
(24.4 mm)
(30.7 mm)
1.160 in.
1.410 in.
(29.5 mm)
(35.8 mm)
1.360 in.
1.610 in.
(34.5 mm)
(40.9 mm)
1.560 in.
1.810 in.
(39.6 mm)
(46.0 mm)
1.760 in.
2.010 in.
(44.7 mm)
(51.1 mm)
1.960 in.
2.210 in.
(49.8 mm)
(56.1 mm)
2.160 in.
2.410 in.
(54.9 mm)
(61.2 mm)
2.360 in.
2.610 in.
(59.9 mm)
(66.3 mm)
2.560 in.
2.810 in.
(65.0 mm)
(71.4 mm)
2.760 in.
3.010 in.
(70.1 mm)
(76.5 mm)
ID Min
ID Max
2.760 in.
3.010 in.
(70.1 mm)
(76.5 mm)
2.960 in.
3.210 in.
(75.2 mm)
(81.5 mm)
3.160 in.
3.410 in.
(80.3 mm)
(86.6 mm)
3.360 in.
3.610 in.
(85.3 mm)
(91.7 mm)
3.560 in.
3.810 in.
(90.4 mm)
(96.8 mm)
3.760 in.
4.010 in.
(95.5 mm)
(101.9 mm)
3.960 in.
4.210 in.
(100.6 mm)
(106.9 mm)
4.160 in.
4.410 in.
(105.7 mm)
(112.0 mm)
4.360 in.
4.610 in.
(110.7 mm)
(117.1 mm)
Locator Size (A)
+1.6 in. (+40.6 mm)
Extension
1.865 in.
#2
(47.4 mm)
1.965 in.
#3
(49.9 mm)
2.065 in.
#4
(52.5 mm)
2.165 in.
#5
(55 mm)
2.265 in.
#6
(57.5 mm)
2.365 in.
#7
(60.1 mm)
2.465 in.
#8
(62.6 mm)
2.565 in.
#9
(65.2 mm)
2.665 in.
#10
(67.7 mm)
2. Place the locators and locator extensions (if
required) into the slots on the mandrel shaft. Make
sure the angled surface of the expanding shaft
mates with the angled surface of the locators (see
Figure 2 for proper locator orientation).
3. Install the appropriate O-ring (see locator size
chart) around the locators to hold them in the
mandrel shaft. The O-ring fits inside the grooves
located on the top of the locators and locator
extensions. Note that the O-ring cannot be
used when mounting in diameters less than
1 in. (25.4 mm).
CAUTION! Failure to install the O-ring can
result in injury.
Model FF-120
ID Min
ID Max
4.360 in.
4.610 in.
(110.7 mm)
(117.1 mm)
4.560 in.
4.810 in.
(115.8 mm)
(122.2 mm)
4.760 in.
5.010 in.
(120.9 mm)
(127.3 mm)
4.960 in.
5.210 in.
(126.0 mm)
(132.3 mm)
5.160 in.
5.410 in.
(131.1 mm)
(137.4 mm)
5.360 in.
5.610 in.
(136.1 mm)
(142.5 mm)
5.560 in.
5.810 in.
(141.2 mm)
(147.6 mm)
5.760 in.
6.010 in.
(146.3 mm)
(152.7 mm)
5.960 in.
6.210 in.
(151.4 mm)
(157.7 mm)
1.760 in.
(44.7 mm)
A
L3076
Rev. C

Publicidad

Tabla de contenido
loading

Tabla de contenido