Operating Instructions SATAjet 1000 K (RP / HVLP) / H (RP)
■ Pull the air micrometer [10-4] out of the gun body.
■ Remove the air piston with air piston spring [10-5].
■ Remove the air piston rod [10-3].
Mount air piston, air piston spring and air micrometer
■ Insert the air piston rod [10-3] in the correct position.
■ Insert air piston with air piston spring [10-5] and air micrometer [10-4]
and grease with SATA high performance grease (# 48173).
■ Press the air micrometer [10-4] into the gun body.
■ Screw the locking screw [10-1] into the gun body.
After installation, adjust the material flow according to chapter 8.2.
9.5. Replace self-adjusting seal (air side)
Replacement is necessary if air escapes under the trigger guard.
Dismantle self-adjusting seal
■ Loosen counter nut [1-3].
■ Screw adjusting screw [1-2] with counter nut out of the gun body.
■ Remove spring and paint needle [9-1].
■ Remove the trigger guard [9-2].
■ Screw the locking screw [10-1] out of the gun body.
■ Pull the air micrometer [10-4] out of the gun body.
■ Remove the air piston with air piston spring [10-5].
■ Remove the air piston rod [10-3].
■ Screw the self-adjusting seal [10-2] out of the gun body.
Mount self-adjusting seal
■ Screw in the self-adjusting seal [10-2].
■ Insert the air piston rod [10-3] in the correct position.
■ Insert air piston with air piston spring [10-5] and air micrometer [10-4]
and grease with SATA high performance grease (# 48173).
■ Press the air micrometer [10-4] into the gun body.
■ Screw in the locking screw [10-1].
■ Mount the trigger guard [9-2].
■ Insert spring and paint needle [9-1].
■ Screw adjusting screw [1-2] with counter nut [1-3] into the gun body.
After installation, adjust the material flow according to chapter 8.2.
9.6. Replace spindle of round / flat fan control
Replacement is necessary if air escapes from the round / flat fan control or
if it is no longer possible to adjust the spray fan pattern.
Dismantle spindle
EN
139