EN
■ Unscrew the countersunk screw [11-2].
■ Remove the control knob [11-3].
■ Screw spindle [11-4] out of the gun body using the SATA universal
spanner.
Mount the spindle
■ Screw the spindle [11-4] into the gun body using the SATA universal
spanner.
■ Position the control knob [11-3].
■ Coat the countersunk screw [11-2] with Loctite 242 [11-1] and screw
handtight.

10. Care and storage

Careful handling together with constant care of the product is necessary
to ensure that the spray gun functions properly.
■ Store the spray gun in a dry place.
■ Clean the spray gun thoroughly every time after it has been used and
every time before changing the material.
Damage from wrong cleaning agents
The spray gun can be damaged by using aggressive cleaning agents to
clean it.
→ Do not use aggressive cleaning agents.
→ Use neutral cleaning agents with a pH of 6 – 8.
→ Do not use acids, caustic solutions, bases, paint strippers, unsuitable
regenerates or other aggressive cleaning agents.
Physical damage from incorrect cleaning
The spray gun can be damaged if immersed in solvent or cleaning agent
or if cleaned in an ultrasonic cleaning machine.
→ Do not place the spray gun in solvent or cleaning agent.
→ Do not clean the spray gun in an ultrasonic cleaning machine.
→ Only use washing machines recommended by SATA.