Calibrating the pedals
You can calibrate the pedals connected to the DAMPER, PEDAL 1 and PEDAL
2 connectors in the back panel. By calibrating a pedal, you let the SV2 un
derstand its polarity and the full range of values sent.
1
Connect all pedals to be calibrated to the SV2. Remember that DAMPER
expects the included KORG DS2H damper pedal (or, as an alternative, the
optional DS1H, or any footswitch pedal), PEDAL 1 expects a footswitch ped
al, and PEDAL 2 can be used to connect either a footswitch or a volume/
expression pedal.
2
Set any volume/expressiontype pedal to its lowest setting.
3
Turn the SV2 off.
4
Keep the Auto/Pedal button pressed, and turn the SV2 on.
5
When the Auto/Pedal LED starts to flash, release the button.
If you do nothing in the next few seconds, the Auto/Pedal LED will turn off,
and the SV2 will complete the startup sequence.
6
While the Auto/Pedal LED is flashing, press the button again. SV2 enters
calibration mode.
7
Now calibrate PEDAL 1 (a footswitch). Completely depress the pedal, then
release it. When you have finished calibrating the pedal connected to the
PEDAL 1 jack, FAVORITES button #1 will turn on.
8
Then, calibrate PEDAL 2. The procedure is different, depending on the use
of a footswitch or a volume/expression pedal:
▪
If you connected a footswitch, completely depress it, then release it.
▪
If you connected a volume/expression pedal, push it all the way forward to
its maximum position.
When you have finished calibrating the pedal connected to the PEDAL 2
jack, FAVORITES button #2 will turn on.
9
Finally calibrate the DAMPER pedal. Completely depress the pedal, then
release it. When you have finished calibrating the pedal connected to the
DAMPER jack, FAVORITES button #3 will turn on.
10
When finished calibrating:
▪
If you calibrated all three pedals connected, SV2 automatically exits calibra
tion mode and continue the startup sequence.
▪
If you calibrated only one or two pedals, press the Auto/Pedal button again
to exit calibration mode and continue the startup sequence.