Installation For Round Surface Mount Electrical Boxes
AA/BB
GG x1
x2
FF x1
Pull supply wires out of the electrical box. Using machine screws (AA or BB), secure mounting strap (FF) to the electrical box. Ensure the side marked "FRONT" is
facing out. Remove protective paper from adhesive face of foam gasket (GG). Pull supply wires through the opening in gasket and adhere gasket to the mounting strap and outer
edge of round surface electrical box.
Pull supply wires out of the electrical box. Using machine screws (AA or BB), secure mounting strap (FF) to the electrical box. Ensure the side marked "FRONT" is facing out.
DD x1
Fixture must be properly grounded. Connect fixture ground wire to ground wire
in electrical box using wire nut (DD). These wires can be either green or bare
copper. Insert black supply lead into connector on black fixture wires and white
supply lead into connector on white fixture wires. Push excess wire into
2N1
electrical box.
NOTE: If eave mounting the fixture, position the sensor head with the adjustment
controls and drain holes facing downward to prevent water damage.
SECURITY LIGHT
(High Beam)
SECURITY MOTION LIGHT SETTINGS
Test
Range
Range
60
1
30
5
Max.
Test
5
10
Max.
OFF
Feet
Minutes
Feet
AREA LIGHT SETTINGS: Decide if area light at lower brightness is to be activated at dusk. Locate right control knob and set to desired time the area light is on. Setting to "Dusk To
Dawn" turns light on from sunset to sunrise.
SECURITY MOTION LIGHT SETTINGS: The motion sensor on this fixture has a built in Dusk-to-Dawn sensor that automatically disables the motion sensor during daylight hours
regardless of motion detection. The additional 360° sensor detects motion up to 14 ft. below.
Test: The motion sensor must be tested prior to starting. To test fixture, restore power to fixture, locate middle control knob and set to "Test." During test mode, the lights will come on
for 40 seconds, regardless of motion detection or the time of day. The light will shut off automatically after 40 seconds. Leave the knob on "TEST" and test the sensitivity by crossing
in the path of the sensor. The light will come on only if it senses movement. Once movement stops, it will turn off in 5 seconds. The test is now complete.
Timer: Once fixture is tested, set middle control knob to desired time the light stays on once motion is detected.
Range: Locate left control knob and set to desired range of motion detection. Rotating knob to "Max" increases the distance of the motion sensor up to 100 ft. NOTE: A higher
sensitivity level increases the chances of a false activation being triggered. For maximum range performance, allow the fixture to operate at any setting (with power) for at least
48 hours.
Manual Mode: To control the security light from inside the home, activate manual "ON" mode by toggling the wall light switch OFF and ON within 2 seconds. The security light will
turn on and stay on for approximately 8 hours, or until the Dusk-to-Dawn sensor detects light in the morning. Once the Dusk-to-Dawn sensor detects light, the manual "ON" mode will
automatically go back to its original settings of the AUTO motion sensor mode.
240°
2N1
AREA LIGHT
AREA LIGHT
SECURITY LIGHT
(Low Beam)
(Low Beam)
(High Beam)
(Full Brightness)
Timer
3hrs
60
1
5hrs
5
3hrs
Dusk To Dawn
Test
10
OFF
Minutes
The 240 degree coverage of the motion sensor is
measured side to side. The sensor is more effective
side-to-side, rather than motion coming straight at it
(in-and-out). Adjust the motion sensor head so that
it detects motion moving across the coverage area.
AA/BB
x2
FF x1
FF x1
EE x1
Position fixture over the mounting strap. Secure long machine screw (CC)
through the center hole of the wall plate and mounting strap. NOTE: Ensure
gasket (GG) properly seals gap between wall plate and electrical box to prevent
water seepage into electrical box. Restore power to the electrical box and
2N1
ensure that the light is functioning properly.
the silicone cap (EE) into the mounting screw opening to prevent water seepage
into the housing.
For recessed electrical boxes, use silicone adhesive caulking (not included) to
seal the gap between the wall plate and the mounting surface to prevent water
SECURITY LIGHT
seepage into the electrical enclosure.
Range
SECURITY LIGHT
Range
(High Beam)
30
60
1
5
5hrs
Range
30
5
Feet
Dusk To Dawn
5
Max.
Test
10
Feet
Minutes
Installation For Recessed Electrical Boxes
2N1
AREA LIGHT
(High Beam)
(Low Beam)
2N1
AREA LIGHT
Range
(Low Beam)
3hrs
30
5hrs
60
1
60
1
5
3hrs
5hrs
Max.
Test
10
OFF
Dusk To Dawn
Minutes
OFF
5
Dusk To Dawn
Max.
Test
Feet
Minutes
The position of the sensor should not exceed 45° below horizontal.
Do not aim the motion sensor at any water, bushes or plants that
45°
may move in the wind, pedestrian traffic, moving cars, etc., as this
will trigger the motion sensor. NOTE: If the sensor arm becomes
loose, readjust the sensor head and tighten the joint screw on the
sensor arm.
For Recessed
For Recessed
Electrical Boxes
Electrical Boxes
Silicone
If the light is functioning properly, fit
AREA LIGHT
(Low Beam)
AREA LIGHT SETTINGS
(Lower Brightness)
Timer
5
3hrs
5hrs
10
OFF
Dusk To Dawn
SECU
(H
2