CL100
Control unit
Type
Power supply
Relay Contact
Operating temperature
PRODUCT DESCRIPTION
The electronic card AS05200 can be used for the management of an external courtesy light, barrier rod lights or an
electromagnet. It is not possible to use the three modalities at the same time.
On the card, there is an input for a detector of external light, so that the courtesy light does not turn on if it is not necessary.
TECHNICAL SPECIFICATIONS/FUNCTIONS
• Green led signalling the START input.
• Input for detector of external light (LUX).
• Trimmer for the setting of the enabling time of the courtesy light output.
• Dip switch for the setting of the operating modalities and for the times control.
• Possibility to connect GBD control units with 12/24 Vdc flashing light output.
• Possibility to connect GBD control units with 230 Vac flashing light output.
INSTALLATION WARNINGS
• Before starting the installation, fit a magnetothermal or differential switch with a maximum capacity of 10A upstream of
the system. The switch must guarantee omnipolar separation of the contacts, with an opening distance of at least 3
mm.
• To prevent possible interference, differentiate and always keep the power cables (minimum cross-section 1,5mm²)
separate from the signal cables (minimum cross-section 0,5mm²).
• Make the connections referring to the following tables and to the attached screen-print. Be extremely careful to
connect in series all the devices that must be connected to the same N.C. (normally closed) input, and in parallel all the
devices that share the same N.O. (normally open) input. Incorrect installation or improper use of the product may
compromise system safety.
• Keep all the materials contained in the packaging away from children, since they pose a potential risk.
• The manufacturer declines all responsibility for improper functioning of the automated device if the original
components and accessories suitable for the specific automation are not used.
• At the end of the installation, always check carefully the proper functioning of the system and the devices used.
• This instruction manual addresses people qualified for the installation of "live equipment". Therefore, good technical
knowledge and professional practice in compliance with the regulations in force are required.
• Maintenance must be carried out by qualified personnel.
• Before carrying out any cleaning or maintenance operation, disconnect the control unit from the mains.
• This control unit may only be used for the purpose for which it was designed. Check the aim of the final use and make
sure that all safety measures are taken.
• Use of the product for purposes different from the intended use has not been tested by the manufacturer, therefore any
work is carried out on full responsibility of the installer.
CL100 / AS05200
Scheda per gestione luce di cortesia, elettromagnete,
luci asta barriera
12/24 Vac-dc
250 Vac 16 A
-20°C +60°C
11
UK