Control Unit; Product Description; Installation Warnings - GiBiDi DSC100 Manual Del Usuario

Ocultar thumbs Ver también para DSC100:
Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

8
UK

CONTROL UNIT

Type
Power supply
Electromagnet power supply
Electromagnet voltage maintenance
Electromagnet power
Relay contact
Operating temperature

PRODUCT DESCRIPTION

The electronic board AS01500 can manage an electromagnet used as accessory on a sliding gate to make the
system reversible or irreversible.
FEATURES / FUNCTION
• Jumper to select installation type.
Possibility of using a limit switch to keep the gate locked in opening.
Automatic functioning at the power on or after a proper command.
Possibility of using the flashing light signal 12/24 Vdc or 230 Vac to activate the functioning cycle

INSTALLATION WARNINGS

• Before proceeding with the installation, fit a magnetothermal or differential switch with a maximum capacity of 10°
upstream of the system. The switch must guarantee omnipolar separation of the contacts with an opening distance
of at least 3 mm.
To prevent possible interference, differenziate and always keep the power cables (minimum cross-section
1.5 mm²) separate from the signal cables (minimum cross-section 0,5mm²).
Make the connections referring to the following tables and to the attached silkscreen. Be extremely careful to
connect in series all the devices that are connected to the same N.C. (normally closed) input, and in parallel all the
devices that share the same N.O. (normally open) input. Incorrect installation or improper use of the product may
compromise system safety.
Keep all the materials container in the packaging away from children since they pose a potential risk.
The manufacturer declines all responsibility for improper functioning of the automated device if the original
components and accessories suitable for the specific application are not used.
After installation, always check carefully proper functioning of the system and the devices used.
This instruction manual addresses people qualified for installation of "live equipment". Therefore, good technical
knowledge and professional practice in compliance with the regulations in force are required.
Maintenance must be carried out by qualified personnel.
Before carrying out any cleaning or maintenance operation, disconnect the control unit from the mains.
This control unit may only be used for the purpose for which it was designed. Check the aim of the final use and
make sure that all safety measures are taken.
Use of the product for purposes different from the intended use has not been tested by the manufacturer, therefore
any work is carried out on full responsibility of the installer.
Mark the automated device with visibile warning plates.
Warn the user that children or animals may not play or stand around near the gate.
Appropiately protect the dangerous points (for example, using a sensitive frame).
DSC100 / AS01500
Electronic board for electromagnet management
230 Vac, single-phase, 50/60 Hz
24 Vdc
12 Vdc
50 VA
250 Vac 16 A
-20°C +60°C
DSC100

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

As01500

Tabla de contenido