BA24
The use of the led card for flashing light (code AU02624) with flashing circuit enabling is suggested.
The "Hammer stroke" function shall not be used with electro-mechanical operators.
The "T3 additional time" function shall not be used with electro-mechanical operators.
C8
FINAL STROKE
BATTERIES USE
If you use 1,9 / 2 Ah fully charged batteries in favourable conditions, a limited number of emergency manoeuvres
is possible without luminous signalling.
If the batteries are used continuously, the use of 6,5 / 7 Ah batteries is suggested.
Enables the final stroke in closing
Functioning:
At the end of the closing time without deceleration, a 3 s impulse with the
power set in the menus F2 and F6 is given, followed by a 2 s impulse with
the power set in the menus F1 and F5.
If the deceleration is enabled, the final stroke is given at the end of the
Y1
deceleration time.
The final stroke is checked by the amperometric level set in the menus
F4 and F8 during the first 3 s and in the menus F3 and F7 in the next 2 s.
The final stroke is not checked by the safety devices (edge/anti-
crushing).
Disabled in sliding modality.
Enables the final stroke in opening and closing
Functioning:
At the end of the opening and closing time without deceleration, a 3 s
impulse with the power set in the menus F2 and F6 is given, followed by
a 2 s impulse with the power set in the menus F1 and F5.
With deceleration enabled, the final stroke is given at the and of the
Y2
deceleration time.
The final stroke is checked by the amperometric level set in the menus
F4 and F8 during the first 3 s and in the menus F3 and F7 in the next 2 s.
The final stroke is not checked by the safety devices (edge/anti-
crushing).
Disabled in sliding modality.
Disables the final stroke function
N
5