Troubleshooting/Repairs - Senco PC1286EU Instrucciones De Operación

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 98
3. Handle the machine carefully. The machine may be
deformed, cracked or broken by dropping, colliding or
hitting it. Never drop, collide or hit the machine.
4. Be sure to inspect the machine every time it is used.
STORING
For the whole time that the compressor is not used
before unpacking it, store it in a dry place at temperature
between -10 C - +50 C and shattered away from weather.
For the whole time that the compressor is not used after
unpacking it, while waiting to start it up or due to
production stoppages, place sheets over it to protect it
from dust, which may settle on the components.
The operational efficiency of the compressor is to be
checked if it is not used for long periods.
TROUBLESHOOTING/
REPAIRS
Compressor is not starting
If the compressor has trouble starting, check the following:
Does mains power match that of the data-plate?
Are power cable extensions of adequate diameter or
length?
Is power supplied to the electrical line?
Compressor not stopping
If the compressor does not stop when maximum pressure is
reached, the tank safety valve comes into operation.
To repair the valve, contact your nearest authorized service
center.
IMPORTANT
● Do not unscrew any connection while the tank is
pressurized - always check if the tank is pressure free.
● Do not do any jobs on the compressor unless you have
disconnected the power plug.
● Temprature in operating ambient: 0 C - +40 C.
● Do not aim jets of water or inflammable liquids on the
compressor.
● Do not place inflammable objects near the compressor.
● During down-time, turn the pressure switch to position
"O"(OFF).
● Never aim the air jet at people or animals.
● Do not transport the compressor while the tank is
pressurized.
● Be careful with regard to some parts of the compressor
such as the head and delivery tubes, as they can reach
high temperatures. Do not touch these parts to avoid
burns.
● Transport the compressor, lifting of pulling it with the
appropriate grips or handles.
● Keep children and animals well away from the machine
operating area.
● If the electrical cable or plug are damaged, do not use
the compressor and contact an authorized service center
to replace the faulty element with an original spare part.
● If the compressor is located on a shelf or on a top above
floor height, is must be secured to prevent it falling
while in operation.
● Do not put objects or your hands inside the protective
grilles to avoid injury to yourself or damaging the
compressor.
● Do not use the compressor as a blunt object toward
things or animals, to avoid serious damage.
● When you have finished using the compressor, always
remove the plug from the power socket.
PNEUMATIC CONNECTIONS
Make sure you always use pneumatic Hoses for compres-
sor air with maximum pressure characteristics that are
adequate for the compressor
11

Publicidad

Tabla de contenido
loading

Tabla de contenido