BE SURE TO USE THE MACHINE IN THE WELL-VEN-
TILATED SHADE.
Using it under high temperature or in the direct sunshine
not only deteriorates its durability, but increases the
temperature of the main body, causing danger to your
safety. Be sure to use it in the well-ventilated shade.
5. DO NOT INSTALL THE MACHINE IN A DUSTY
PLACE. INSTALL THE MACHINE IN THE
APPROPRIATE DIRECTION.
Install it appropriately.
6. NEVER INSTALL THE MACHINE IN THE RAIN OR
7. IN A PLACE SPLASHED WITH WATER OR
EXPOSED TO HIGH TEMPERATURE.
Using it in the wet condition could cause an electric
shock or a short-circuit, resulting in a fire due to
burnout or ignition.
8. NEVER BLOCK A VENTILATION OPENING OR USE
THE MACHINE IN A BOX OR NARROW PLACE.
Neglect of this may generate abnormal heat, causing
a trouble or an accident.
9. NEVER SIT OR PLACE AN OBJECT ON THE TOP
OF THE MACHINE.
Neglect of this could cause a trouble or break it.
● Unpack the compressor and check for any deciency,
damage caused during transportation and loose bolts
and screws.
● Be sure to install the compressor on a flat floor, with
leg rubber underneath it: the allowable tilt angle of the
floor is up to 10 degrees. If the installation floor is
tilted and slippery, ensure that the compressor does
not move during operation. Do not use it on a shelf or
a stand where it may fall or tumble.
● Install the compressor at the distance of 1m or more
from the wall to secure sufficient ventilation and cooling.
● The adequate room temperature is +5 C to+ 30 C.
(0 C to +40 C at maximum)
WARNING
Do not use the compressor in any place where the
temperature is 0 C or less or the ambient temperature
exceeds +40 C.
OPERATION
Carry the compressor in a proper manner by holding its
grips with both hands. Don't turn it over or lift it with a
hook and rope.
6
ELECTRICAL CONNECTION
The internal electrical wiring has been all completed.
Take out a power cord from the handle section to connect
it to a plug socket. The compressor comes with a 2-pole
power plug plus earthing. It must be connected a power
plug socket equipped to power plug socket equipped with
earth connection.
WARNING
The compressor must be connected to the power plug
socket protected by an appropriate circuit breaker
(magnet thermal switch).
START-UP
The power source must be is single-phase 220/230V or
110V/120V. Make sure that the power source is correct.
Allowable tolerance is within +/-10%.Turn the switch to
"O" (OFF) position "O". Fit the plug in the power socket
and turn on the switch to "1"(ON), start the compressor,
turning the pressure reaches maximum value and
restarts it when falls to minimum value.The compressor
stops when it reaches maximum operating pressure and
restarts automatically when the pressure inside the tank
drops.After connecting the compressor to the power line,
load it to maximum pressure and check exactly how the
machine is operating.