SICK SureSense HL18 Manual De Operación página 4

Ocultar thumbs Ver también para SureSense HL18:
Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 36
8017290 | SICK
Subject to change without notice
Image: E
5
Sensor which it is not possible to set: The sensor is set to factory settings and rea‐
dy for operation.
After alignment is complete, move a non-transparent object into the path of the be‐
am. Refer to graphics C and G to check the function. If the switching output fails to
behave in accordance with graphic C, check application conditions. See section
Fault diagnosis.
100 %
0 %
Image: F
Sensor with potentiometer:
The sensitivity is adjusted with the potentiometer (type: 270°). Clockwise rotation:
operating reserve increased; counterclockwise rotation: operating reserve reduced.
We recommend setting the potentiometer to "Maximum". A lower operating reserve
may be necessary for depolarizing surfaces, very small objects, or translucent ob‐
jects.
The sensor is adjusted and ready for operation. Refer to graphics C and G to check
the function. If the switching output fails to behave in accordance with graphic C,
check application conditions. See section Fault diagnosis.
Image: C
100 %
100 %
0 %
0 %
3
COMMISSIONING
100 %
100 %
0 %
0 %
3

Publicidad

Tabla de contenido
loading

Tabla de contenido