en | 10 | 1 687 010 607
CRINs with internal connections
sure connection of the high-pressure rail of the DCI 700
(3).
5
1
4
7:
Bosch CRIN port
(1) Inlet connector 1 683 386 166
(2) High-pressure connection with adapter nut
(3) High-pressure rail
(4) Connection adapter (special accessory)
(5) Bosch CRIN
There is a dedicated connection adapter for all
Bosch CRINs that can be tested (see
accessories").
---Separator---
4.5
Holding device 1 688 120 185
The holding device 1 688 120 185
port heavy connection adapters (2), e.g. the connection
adapter A7E, to prevent them from slipping from the
Bosch CRIN.
Before the fitting of the Bosch CRIN, the holding device
(1)
is slid onto the guiding rod (4). After the injection
chamber has been attached to the Bosch CRIN, the
(1)
holding device
is swiveled under the connection
(3)
for support. The holding device is clamped
adapter
tight by turning the tensioning lever
1 689 989 415 | 2020-03-24
(5)
to the high-pres‐
3
2
8 "Special
(1)
is used to sup‐
(2)
clockwise.
2
1
3
4
8:
Holding device 1 688 120 185
(1) Holding device
(2) Tensioning lever
(3) Connection adapter for CRIN
(4) Guiding rod
---Separator---
4.6
Adapter cable 1 684 465 849
The adapter cable 1 684 465 849 can be used to con‐
nect a Bosch CRIN to the injector actuation port of the
DCI 700.
The adapter cable 1 684 465 849 is used to actuate the
Bosch CRIN electrically.
1 684 465 849
458930-03_Pal
9:
Adapter cable 1 684 465 849
(2)
For testing, the plug
of the adapter cable
1 684 465 849 is plugged into the injector actuation
(1)
port
and locked. The two connectors
(4)
ed to the contacts
of the Bosch CRIN(5). It is not
necessary to observe any particular sequence of polari‐
ty.
(3)
are attach‐
Robert Bosch GmbH