Descargar Imprimir esta página

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

Timer setting (see relative chapter)
Sleep setting (see relative chapter)
9.3

SETTINGS MENU

The SETTINGS menu allows to act on the boiler operating mode:
EN
A. Language.
B. Cleaning (displayed only when the boiler is switched off).
C. Feed screw loading (displayed only when the boiler is switched off).
D. Tones.
E. External thermostat (activation).
F. Auto Eco (activation).
G. Eco-Shutdown T (default 10 minutes).
H. Pump on T (default 50°C).
I.
Auxiliary boiler (default deactivated).
j. Pellet recipe.
k. Smoke rpm % ventilation.
L. Maximum power (1-5 - default 5).
M. Components test (displayed only when the boiler is switched off)
N. "Chimney sweep" function (activated only when the boiler is switched on, for field emissions test).
O. System configuration.
P. Season.
Q. Technical menu.
NOTE: Some of the items listed above cannot be activated in certain "system configurations".
a - Language
To select the language act as follows:
• Press the "menu" button.
• Scroll to "Settings" using the arrows
• Press "menu" to confirm.
• Scroll to "language" using the arrows.
• Press "menu" to confirm.
• With the + - keys select the language of interest (IT/EN/DE/FR/ES/NL/PL/DA)
• Press "menu" to confirm and "esc" to exit.
b - Cleaning
To select "Cleaning" (only when the boiler is switched off) act as follows:
• Press the "menu" button.
• Scroll to "Settings" using the arrows
• Press "menu" to confirm.
• Scroll to "Cleaning" using the arrows.
• Press "menu" to confirm.
• Select "On" with the + - keys.
• Press "menu" to confirm and "esc" to exit.
c - Feed screw loading
To select "Feed screw loading" (only when the boiler is switched off) act as follows:
• Press the "menu" button.
• Scroll to "Settings" using the arrows
• Press "menu" to confirm.
• Scroll to "Feed screw loading" using the arrows.
• Press "menu" to confirm.
• Select "Enable" with the + - keys.
• Press "menu" to confirm and "esc" to exit.
d - Tones
This function is disabled by default, so to enable act as follows:
• Press the "menu" button.
• Scroll to "Settings" using the arrows
• Press "menu" to confirm.
• Scroll to "tones" using the arrows.
• Press "menu" to confirm.
70