welding with covered electrode.
4-
Symbol for power supply line: monophase alternating
voltage.
5-
Protection rating of casing: IP21 or IP22: it is protected
against solid foreign bodies of diam. 12.5mm (e.g.
fingers) and against drops of water falling vertically
(IP21) or with an inclination to the vertical of up to 15°
(Ip22).
6-
Performance of welding circuit:
- U0: no-load voltage (welding circuit open).
- I2: Normal welding current; indicates the welding
current adjustment range (minimum - maximum) at the
corresponding arc voltage.
- Ø: diameter of electrodes that can be welded.
- nc is the reference number of electrodes that can be
welded, starting with the welding machine at ambient
temperature, until the thermostat cuts in for the first
time.
- nc1 is the reference number of electrodes that can be
welded in one hour starting with the welding machine at
ambient temperature.
- nh is the AVERAGE VALUE for reference number of
electrodes that can be welded between thermostat
reset and cut in.
- nh1 is the reference number of electrodes that can be
welded in one hour starting with the welding machine at
running temperature.
7-
Specifications for the power line:
- U1: Alternating voltage and power supply frequency
for the machine (allowed limits ±15%)
-
: Size of delayed action fuses to be provided
to protect the line
- I1max: Maximum current absorbed by the line
8-
H
: transformer insulation class
9-
Manufacturer's serial number. Machine identification
(indispensable for technical assistance, requesting
spare parts, discovering product origin).
Note: The plate example given shows the meaning
of the symbols and figures; the exact rating values
for the machine in your possession should be read
directly on the rating plate of the machine it self.
EN 60974-1: European Standard relative to welding
generators
1-
EUROPEAN Norm of reference, for safety and
construction of arc welding machines.
2-
Symbol for internal machine structure: inverter
transformer .
3-
Symbol for welding procedure provided: manual arc
welding with covered electrode.
4-
Symbol for power supply line: monophase alternating
voltage.
5-
Protection rating of casing: IP21 or IP22: it is protected
against solid foreign bodies of diam. 12.5mm (e.g.
fingers) and against drops of water falling vertically
(IP21) or with an inclination to the vertical of up to 15°
(IP22).
6 - Performance of welding circuit:
- U : maximum peak no-load voltage (welding circuit
0
open).
- I /U : current and corresponding normalised voltage
2
2
[U2 = (20+0.04 I2) V] that the machine can deliver
during welding.
- X: Duty cycle: indicates the time for which the machine
can deliver the corresponding current (same column).
Expressed in %,on the basis of a 10min cycle (e.g. 60%
= 6 minutes work, 4 minutes wait; and so on).
- A/V-A/V: Indicates the welding current adjustment
range (minimum - maximum) at the corresponding arc
voltage.
7-
Technical specifications for power supply line:
Fig. C
- U : Alternating voltage and power supply frequency of
1
machine (limit allowed ±15%):
- I
: Maximum current consumed by the line.
1max
- I : maximum effective current consumed
1eff
8-
:
Value of delayed action fuses to be used to
protect the power line.
- Symbols referring to safety standards
9-
Manufacturer's serial number. Machine identification
(indispensable for technical assistance, requesting
spare parts, discovering product origin).
Note: The plate example given shows the meaning
of the symbols and figures; the exact rating values
for the machine in your possession should be read
directly on the rating plate of the machine it self.
THERMOSTATIC PROTECTION
This welder is automatically protected from thermic
overheating (thermostat automatic re-start). When the
windings reach performance temperature, the protections
cut off the supply circuit, igniting the yellow lamp on the front
panel (3). After a few minutes' cooling the protection will
reopen the supply line and turn off the yellow lamp. The
welder is ready for further use.
INSTALLATION
SITE
Locate the machine in an area where openings for cooling
air are not obstructed (forced circulation with fan); check that
conductive dusts, corrosive vapours, humidity etc., will not
enter machine.

CONNECTION TO MAINS

-
Before making any electrical connection check that the
mains voltage ratings of the data table correspond with the
voltage of the workplace. The machine is to be fed with two
conductors (2 phases or phase-neutral) plus a third
separate one designed for the protective earth connection
(PE); this conductor is coloured yellow/green.
For welders with double voltage supply, it is necessary to set
the blocking screw of the voltage-reverse switch in the
position corre sponding to the voltage really available (see
example below).
PLUG: CONNECT TO THE MAINS CABLE A
STANDARDIZED PLUG OF ADEQUATE CAPACITY (2P +
T) AND SET A MAINS SOCKET EQUIPPED WITH FUSES
OR AN AUTO MATIC SWITCH.THE CORRECT
TERMINAL IS TO BE CONNECTED TO THE GROUND
CONDUCTOR (YELLOW-GREEN) OF THE MAINS
V O LT AG E S U P P L Y. T A B L E 1 S H O W S T H E
RECOMMENDED AMPERE VALUES OF DELA YED TYPE
FUSES SELECTED ACCORDING TO MAXIMUM
NOMINAL MAINS CURRENT OF WELDER AND
NOMINAL MAINS VOLTAGE.
WARNING
Failure to observe the above rules will make ineffective
the safety system installed by the manufacturer (Class
1) with resulting risks for persons (eg. electric shock)
and objects (eg. fires).
REPLACING THE POWER SUPPLY CABLE
THIS OPERATION MUST BE CARRIED OUT BY
SKILLED PERSONNEL!
Before replacing the cable, find the screw connection
terminals
L1 and L2 on the rocker switch and/or rotary switch. (Fig - E)
CONNECTION OF THE WELDING CABLES
- WORK CABLE
- 27 -
Fig. D
TABLE 1