Peak and Hold PRO Injector Driver
5. Installation
Battery must be unpluged for the installationy. It is very important that the cable
length is the shortest possible and that all exceeding unused parts of wires are
cut off. Never roll up the excess of any wire in the cable; by doing so, interference
problems, which are very usual with any electronic device, are avoided.
The harness must be protected from contact with sharp vehicle body parts that
might damage the wires and cause short circuit. Watch out for wires passing
through holes, and use rubber protectors or any other kind of protective material
to prevent any damage to the wires. At the engine compartment, pass the
EN
wires through places where they will not be subject to excessive heat and
will not obstruct any mobile parts in the engine. Always, when possible, use
wires sleeves.
5.1 Wiring diagram
Output Channel 4
Input Channel 8
Ouput Channel 8
Black/white Power Ground
-
Output Channel 7
Output Channel 6
12V input from relay
P&H PRO Communication
Output Channel 5
Input Channel 5
CAN A (-) LOW
Input Channel 6
CAN A (+) HI
Input Channel 7
6
2
5
1
3
4
8
9
10
11
12
14
15
16
17
18
20
21
22
23
24
Input Channel 4
Output Channel 3
Black/white - Power Ground
Output Channel 2
Black/white - Power Ground
6
7
12V input from relay
13
Output Channel 1
19
Input Channel 1
25
26
Input Channel 2
Black/white - Power Ground
Input Channel 3
Output for injector's relay