Peak and Hold PRO Injector Driver
7.3 ECU safety protection
Once the PRO Injector Driver protection have been configured, the ECU Alert
Settings should be configured.
•
•
•
•
ECU alerts allows choosing between screen alert only, safe mode, or engine
EN
shut off
7.4 Status Events Diagnosis
Menssage
Driver Self Check
Unplugged Injector
Injector short-circuit
Channel Overheat
14
Open the FTManager latested version software and Read ECU.
Go to Alert Settings, at the left panel
Activate and select the action for both P&H PRO Injector Driver.
Write ECU
Possible Cause
PRO Injector Driver internal
temperature sensor anomaly
was detected
Injector failure or Injector duty-
cycle at 100%
Miswired injector or harness
Overheat at one specific
failure.
channel
Solution
Call FuelTech Support to send the
PRO Injector Driver for inspection.
Check the injector
Check harness and injector
connector
Check the module installation spot,
we recommend a high ventilation
spot